PLUMBING ALTERATION - DEMO AND INSTALLATION OF DOMESTIC WATER AND VENT PIPING ONLY
Installing 4 total fireplaces. 3 are gas units & 1 is water vapor. Installing on 2nd floor patio & clubroom, 7th floor patio & sky lounge. NOT doing gas line or elecrical. Make: Stellar Model: IDOD Make:Opti-myst Model:CDFI500 Make: Starfire: Model: Fi
CONVERT EXISTING MAIN FLOOR REAR ENTRY/ MUD ROOM INTO NEW HALF BATHROOM IN EXISTING SINGLE FAMILY HOUSE. AAJ (PROJECT DOX PLANS). DEMOLITION WORK: - REMOVE TWO WINDOWS AND ONE EXTERIOR DOOR ON REAR ELEVATION WALL TO ALLOW FOR NEW RENOVATION WORK TO
Add 1/2 bath and stackable washer/dryer combo
relocate demising wall between suites 100 and 200. const type 2b sprinklered B and S1 occupancies architect: pope design group
FIREPLACE
REPLACE EXISTING WOOD RETAINING WALL WITH POURED CONCRETE RETAINING WALLS. WALL MUST NOT CROSS ON TO ALLEYWAY. WALL MUST BE WITHIN PROPERTY LINE. WALL HEIGHT DOES NOT EXCEED THE ENGINEERS DRAWINGS PER APPLICANT. (JJL) ENGINEER: PAUL SCHMNOWSKI #40126
(DMH - ProjectDox) RECONSTRUCT CONCRETE LANDING & STEPS AT REAR ENTRY OF SFD OVER NEW FROST FOUNDATION. SEE ENGINEERED FOUNDATION FROM PAUL SCHIMINOSKI, #40126. SEPARATE PERMIT APPLICATION FOR RETAINING WALL UNDER BLDG993631. APPROVED PLANS
Replacement of AC
interior remodel for workshop and accessory gallery area (less than 750 sq ft and serves the workshop area). certificate of occupancy required: no const type: 3b occupancy: B 2020 MSBC sprinklered: yes Tenant: Leonardo's
INSTALL A SOLAR PV SYSTEM ON ROOF OF BUILDING. (MAA) ENGR BERNARD STROH 14269 COLLECTOR CAPACITY __104.2__ KW SOLAR CHECKLIST ATTACHED. MEETS OR EXCEEDS SRCC CERT PER MN RULES 1325.1100 Subp.5a as applicable. ADDITIONAL PERMITS:
MECHANICAL UPGRADES, SOME STRUCTURAL WORK. NO CHANGE TO EXITING OR OCCUPANT LOAD. (JJL) certificate of occupancy required no special inspections required yes -AET const type: IIB ASSUMED occupancy: NO CHANGE 2020 MSBC
Replace 17 windows and 2 entry doors within existing openings.
INSTALL NEW NON TESTABLE BACK FLOW DEVICE FOR BOILER
INSTALL GAS PIPING TO 5 GAS GRILLS, 3 FIRE PITS AND 1 FIREPLACE
Temp heat - six 500,000 BTU, one 800,000 BTU
ROOF STRUCTURE MODIFICATIONS TO AN EXISTING DUPLEX RE-FRAME SIDE OF 2ND FLOOR ROOF, INSTALL 3 WINDOWS This permit does not establish new bedroom space. Structural Engineer: Phillips #47507 The building inspector must approve the restoration of fire
1. APPROVAL OF THESE PLANS SHALL NOT BE CONSTRUED AS PERMITTING A VIOLATION OF THE BUILDING CODES OR ANY OTHER LAWS OR ORDINANCES. 2. PTAC units condensate shall be piped and discharged into condensate riser as specified. 3.
Complete tear off down to decking. Inspect the decking. Install ice and water shield, felt, shingles, replace flashing and vents.
CONSTRUCT 7 STORY 210 UNIT APARTMENT BUILDING WITH BASEMENT LEVEL PARKING. 210 units total. F&F issued under separate permit 5 type A units provided all remaining units are type B. certificate of occupancy required: yes CONST TYPE: 3a OVER 1a PODIUM