Replace curtain wall and windows Fire stop SI CAIM approved 8/22/22 attached in ELMS ADD $2500 UNPERMIT WK FEE BUT 50% PR FEE certificate of occupancy required no special inspections required by Braun to document conformance to EJ 366413e - Fire res
FOOD - CV6 REMODEL RELOCATE FIXTURE
remodel and CV-6 equipment replacement certificate of occupancy required NO special inspections required NO const type: I-A occupancy: I-2 2015 MSBC occupant load: NO CHANGE sprinklered: YES Tenant: ABBOTT NORTHWESTERN F
Remodeling of storage spaces certificate of occupancy required: NO***** special inspections required: NO***** const type: I-A ***occupancy: B ***2015 MSBC***** occupant load: NO CHANGE ***** sprinklered: YES ***** Tenant: ABBOTT
ADDITION OF FREE STANDING PORTE COCHERE,EMERG DEPT. DEMOLITION, ADDITION OF 3 STEEL COLUMNS COVERED IN CONCRETE TO SUPPORT ROOF STRUCTURE AND THE ROOF SYSTEM CONSISTS OF GALVANIZED WIDE-RIB METAL DECK, STEEL STUD FRAMING AND METAL PANELS. Special Inspect
Remodel for new new medical equipment certificate of occupancy required NO special inspections required YES const type: I-A occupancy: 1-2 2015 MSBC sprinklered: YES Tenant: ABOTT NW Floor(s): LEVEL 1 sac: __charges __credi
Providing exhaust fan for sterilization cabinet.
HOT WATER PIPING / DUCTS & VAV'S FOR 1ST & 4TH FLOORS
ELEC-Abbot-1st fl- interior TI and equip repl. certificate of occupancy required no special inspections required yes no const type: !-A occupancy: I-2 2015 MSBC occupant load: __no change___ sprinklered: yes energy code cha
(DMH#2) TEAR OFF & REROOF SELECT ROOF AREAS TO HOSPITAL FACILITY. REMOVE TO CONCRETE & METAL DECKS, INSTALL VAPOR BARRIERS AS REQUIRED, TAPERED ISO. INSULATIONS, 1/2" COVER BOARDS, AND BALLASTED AND FASTEND EPDM MEMBRANES. 6 SELECT ROOF AREAS IDE
Reconfiguration of HVAC system including seventeen VAV boxes with hydronic heating coil, hydronic piping, supply diffusers, return grills and all associated duct work. Refer to attached drawings.
CONVERT SPACE TO RETAIL PHARMACY __ certificate of occupancy required no ** special inspections required no ** const type: I-B _ occupancy: I-2 and B (nonseparated) _ 2015 MSBC ** occupant load: _24____ *** sprinklered: yes *** 20% accessibility upgrades_
INSTALL NEW UTILITY SET FAN AND INSTALL CONDENSATE DRAIN INTO STAINLESS DUCT
INSTALL WALK IN COOLER AND REFER UNIT
Install 1 plumbing vent to accommodate new floor plan layout.
Replacing supply and return diffusers with associated ductwork.
REMODELING FOR SCANNER REPLACEMENT - IR RM C. No structural work, *** certificate of occupancy required : no ** special inspections required no *** const type: IA *** occupancy: I-2 *** 2015 MSBC *** sprinklered: yes *** energy
LEVEL 1 OF COURAGE KENNY BUILDING AND LEVEL 1 OF VIRGINIA PIPER BUILDING. DEMO OF THREE AREAS WITHIN THOSE 2 BUILDINGS. SOME MISC INTERIOR WALL FRAMING. NO STRUCTURAL WORK. ALL NON COMBUSTIBLE CONSTRUCTION. (JJL) ARCHITECT: LEO A DALY DANIEL ABELN #
HVAC system for partial renovation. They are adding new air handling unit, VAV boxes, 2 small exhaust fan and all associated duct work and supply and return air diffusers and grills. Refer to attached drawings.
Upgrading HVAC system for part of building, adding one fan-coil and two VAV boxes. replacing supply fan, return fan, final filter section, pre-filter section of existing air handling unit and all supply and return air duct and registers for new layout of
NEW RESTROOM AT 10TH AVE FACILITY FOR MEDICAL RECORDS OFFICE
FOR COURAGE KENNY AREA - 7 OXYGEN OUTLETS & ZONE VALVE BOX
alterations to parking structure office to allow for new customer pay station. sck
PARTIAL RENOVATION OF FIRST FLOOR CURRENTLY CALSSIFED I-2. FIRST FLOOR FUNCTIONS AS OUT PATIENT CLINIC, PHARMACY, AND OFFICES.(MAA) CURRENT OUT PATIENT CLINIC WILL BE CONVERTED INTO ONCOLOGY INFUSION CENTER AND THE ENTIRE FIRST FLOOR WILL BE RECLASSIFED