Install a 3-zone system allowing for separate control of temperature in 3 different areas. Includes 3 zone panel, 2 new Honeywell focus Pro200 thermostats, 8" Barometric bypass damper. 3 motorized dampers: 10x20m 10x10m 10x12m ZONES: 1- Upper level primary 2- Mid level bedrooms 3- Main floor & basement *Existing thermostat wires are adequate. LL family room: Add 1 supply Add 1 10" return 2 existing and 1 new supply to have commercial lay-in diffusers installed in grid ceiling. LL Laundry: Add 1 new supply Correct dryer vent per code Main level: Install new grills & registers throughout project. (8) 14x6 wall return (9) 12x6 wall supply (3) 2x12 floor supply LL bedroom: Add 1 additional supply Add 1 return, connect to main duct in soffit at bathroom. Add 1 supply to storage room. *Requires removal of ceiling in LL bedroom and at soffit in LL bathroom. (by others)
Window install (1)
Add lower level laundry and replace fixtures at main level half bathroom