Tear off existing vinyl siding. New gutters and downs are getting installed, so existing can be discarded. Remove and patch over existing gable vent. OSB provided. Wrap house in Tyvek. Install new Market Square dutchlap siding in Espresso in all areas except the front gables. Install Clay vinyl shakes in the front gables with a 2x6 white aluminum wrapped band board below. 1 Clay corner to be installed in the Shake area on the front bump out. Install white center vent soffit and white prebent fascia. Wrap 1 window and 1 door on the right side in white aluminum. 2 story house in back. Park dumpster on the right side of the driveway. Production Note: Electrician needed for lights and outlets RPU is electric utility
RPZ Install
NEVER BEFORE BATH FAN IN UPSTAIRS ATTIC BATHROOM
Wire new bath fan
ADDITIONAL SCOPE OF WORK ADDED TO ORIGINAL PERMIT # R25-1413CE Installing new panel NR-306 to feed (5) new 6-50R receptacles in lab 03-51. Mayo# ROMS25C0010/MS 03 Renovate Lab Space/Medical Sciences Egan Foreman: John Prudoehl 507-208-5584 Egan Job# 613745-910
Replace existing air handler in Unit 3 condenser located on roof updating ductwork adding supply to bathroom. Filter grill on return overflow with pan sensor.
TEMPERATURE CONTROLS ROMS25C0010
TEMPERATURE CONTROLS ROMS24C0010
Replace furnace and thermostat
Replace water heater
ROMS25C0010 - Renovation of Lab Space, Reworking VAV's and Fan Coils
FURNISH AND INSTALL DUCTWORK, GRD, FAN COILS, DAMPERS
Electrical work for Mayo# ROMS25C0010/MS 03 Renovate Lab Space/Medical Sciences Egan Foreman: John Prudoehl 507-208-5584 Egan Job# 613745-910
Bob Sanderfoot/ROMS25C0010/MS 03 Renovate Lab Space/Medical Sciences
AC replacement
Rehook new ac installed by BNC
Water heater replacement
All plumbing work and materials related to this project. Mayo Job # ROMS24C0010 - HTM Lab Space Remodel Harris Job # 0800461-N5080
All hydronic work and materials for this project. Mayo # ROMS24C0010 - HTM Lab Space Remodel Harris Job # 0800461-N5080
Mechanical work related to all the HVAC work and materials for this project. Mayo # ROMS24C0010 HTM Lab Space Remodel Harris Job # 0800460-N5080
Hillary Hughes/ROMS24C0010/ HTM Lab Space Remodel/ Basement Level
ROMS24C0010 - Remodel lab space to include new lighting, lighting control convenience outlets and panelboard. Foster job# 225032
Includes house and garage. Does not include rear EPDM roof. Remove shingles and underlayment to deck. Install new edge metal, new ice and water at eaves and valleys, new underlayment, new CT Landmark Shingles with accessories. New stack and vents.
REPAIR OH ELECTRIC SERVICE DAMAGED BY STORM AND UPGRADE TO BYPASS METER SOCKET WINKELS JOB #2552716
The correct address to the site is 321 1/2 S Broadway. Accela won't allow the address to be searched. The smoke detector is within the unallowed circumference of the fan. Plan to extend the power source at least three feet away from the tip of the fan with wiremold.