REMODEL SURGERY DEPT FOR AN IMRI-OR, DIAGNOSTIC RM AND CONTROL RM. WORK WILL IMPACT OR#1, OR#9, STERIL CORRIDOR AND CORRIDORS. DB approved post-issue revisions to A, F, G, I, & S sheets submitted 9/5/22. The revised MEP sheets must be reviewed by MEP
REMOVE/INSTALL TELECOMMS EQUIPMENT ______ Maintain fire-caulking/fire-rating at any penetrations. ______ Rated Exit Stair Enclosures are not allowed as a raceway for any of the installation. ______ See engineer's letter THOMAS L. MACH - 42357 -----
remodel of 6th floor for PICU rooms and staff support areas. sck certificate of occupancy required no const type: 1a occupancy: I2 2020 MSBC sprinklered: yes architect: mclane
Relocating supply diffusers, thermostats and VAV boxes per attached plans.
HVAC system, including duct modification and installing two negative pressure exhaust fans and all associated grills. Refer to attached drawings.
Modifying the return ducts and adding a new exhaust. Refer to attached drawings.
Heating 168MBH and ventilation 5000 CFM, & AHV, VAV boxes ______ Inspection required. Contact inspector to schedule inspection.
RADIOLOGY SUITE REMODEL AT LEVEL 2 (MAA) certificate of occupancy required NO mechanical plans/letter of means of compliance submitted\ YES special inspections required NO const type: I A occupancy: I2 2015 MSBC 20% accessibilit
ADD 2 UTILITY SET FANS ON ROOFTOP / ROUTE EXHAUST DUCTS THRU ALL FLOORS TO APPLIANCE / GENERAL WILL INSTALL 2 HOPUR RATED ENCLOSURE AROUND DUCTS FROM END TO END.
TELECOM ALTS - VERIZON, REPLACE EQUIPMENT AT EXISTING ROOFTOP INSTALLATIONS. DTC-2 NEW REPLACEMENT EQUIPMENT IS SIMILAR OR SMALLER THAN EXISTING. REMOVE 3 ANTENNAS, 3 RRU'S AND 6 AMPS, REPLACE WITH 3 ANTENNAS, 3 RRU AND 6 DWDM FIBER BOXES. ARCHITE
Replacing 12 electric humidifier by dristem from 36-48 lb/hr. No other work.
REMODEL CPD EQUIPMENT SPACE certificate of occupancy required NO special inspections required YES - FIRE RATED PENETRATIONS const type: occupancy: I-2 2015 MSBC occupant load: NO CHANGE sprinklered: YES Tenant: CHILDRENS HO
HIGH PRESSURE STEAM PIPING & DUCT ALTERATIONS PER ENGINEERED DRAWING
RELOCATE STERILIZERS ADD NEW STERILIZER
VENT/MAKEUP AIR / cap existing supply / balance relocated existing exhaust / relocate diffuser
HEAT/VENT/AC
Non-structural remodel of 4th floor CVICU lobby Special inspections: fire rated penetrations and applied fire protection ARCHITECT: HDR - Brent Benusa #51041
Remodel first floor for new MRI, approx. 4,000 s.f. of space. Minor remodeling in basement, second and 9th floors. Special Inspections required SAC - NA ARCHITECT: HDR - Brent Benusa #51041 ENGINEER Paulson Clark - John Paul Gille #21476
4th Floor - Suites 400 A and B
14 fixtures
DUCTWORK MODIFACTIONS TO LOWER LEVEL PER ENGINEERED DRAWINGS
12 lavs and 1 toilet childrens hospital