2450 RIVERSIDE AVE, Minneapolis
Room M2728: Demo sink, salvage for reuse. Cap piping at mains. Connect piping in lower level at new sink location, reinstall salvaged sink. Demo med gas, salvage wall head for reuse. Route new piping per plans, reconnect salvaged outlets in new wall. Nass
2450 RIVERSIDE AVE, Minneapolis
HVAC replacing two main rooftop units, remodeling of 5th & 6th floors adding VAV boxes, exhaust fans, hydronic pumps, finned tube radiation, hydronic piping, heat exchanger, supply diffusers, return grilles and all associated duct work. Refer to attache
2450 RIVERSIDE AVE #WEST BLDG, Minneapolis
Remodel of existing space on 5th and 6th Floor of Fairview West Bank Hospital.
2450 RIVERSIDE AVE #EAST BLDG, Minneapolis
complete remodeling of hospital floors 5 and 6. add new stair enclosure. sck certificate of occupancy required no special inspections required yes const type: 1a occupancy: I2 2020 MSBC sprinklered: yes architect: AECOM en
2450 RIVERSIDE AVE, Minneapolis
Tenant remodeling certificate of occupancy required: NO special inspections required: NO const type: I-A occupancy: B 2020 CONSERVATION CODE - WORK AREA METHOD - LEVEL 2 ALTERATION occupant load: NO CHANGE sprinklered: YES Tenant:
2450 RIVERSIDE AVE #WEST BLDG, Minneapolis
Remodeling of 4 toilet rooms on floors 2 + 4 certificate of occupancy required: NO special inspections required: NO construction type II_B occupancy: B LEVEL 2 ALTERATION PER 2020 CONSERVATION CODE occupant load: NO CHANGE sprinkle
2450 RIVERSIDE AVE, Minneapolis
Chiller platform structure renovations and addition ENGINEER: MBJ - Mark Cackoski #25835
2450 RIVERSIDE AVE, Minneapolis
HVAC system, adding two new air cooled chillers, five hydronic pumps, 4 plate and frame heat exchangers, glycol fill station, buffer tank and all associated piping. Refer to attached drawings.
2450 RIVERSIDE AVE, Minneapolis
2ND FL IR STE - 2 WALL HUNG SINKS & 1 SS SINK
2450 RIVERSIDE AVE, Minneapolis
Reconfiguration of HVAC system including six VAV boxes, four heating coils, , one split system, hydronic piping, supply diffusers, return grills and all associated duct work. Refer to attached drawings.
2450 RIVERSIDE AVE #EAST BLDG, Minneapolis
remodel existing interventional radiology suite on 2nd floor - west bank east building. sck The total square footage to be remodeled is approximately 2,250 SF. certificate of occupancy required no const type: 1a occupancy: I2 202
2450 RIVERSIDE AVE, Minneapolis
Reconfiguration of HVAC system including replacement of two air handling units with energy recovery, replacing heating coil for one air handling unit, VAV boxes, Air valves, exhaust fans, two heat exchangers, hydronic pumps, hydronic piping, supply diffus
2450 RIVERSIDE AVE, Minneapolis
FOR 4TH FLOOR MATERNITY: REPLACE SINK
2450 RIVERSIDE AVE, Minneapolis
ICU #10A - BATHROOM REMODEL
2450 RIVERSIDE AVE, Minneapolis
Reconstruct East wing on 10th floor of B certificate of occupancy required no special inspections required yes - fire stop and structural per Sched of SI const type: 1B occupancy: I-2 2015 MSBC occupant load: _no change sprinkl
2450 RIVERSIDE AVE, Minneapolis
process piping.
2450 RIVERSIDE AVE, Minneapolis
Remodel Maternal Fetal Meds certificate of occupancy required no special inspections required no const type: II-B occupancy: B 2020 MSBC; MN Conservation Code Alterations Level 2 occupant load: _89____ sprinklered: yes 20% ac
2450 RIVERSIDE AVE, Minneapolis
2450 RIVERSIDE AVE, Minneapolis
ELECTRONIC SUBMITTAL InteriorDemo12RoomsEastWing10thFlrBldgA All fire rated elements within the scope of work must be evaluated by an approved Special Inspector to determine required restoration in the documents and work of the future remodeling project.
2450 RIVERSIDE AVE, Minneapolis
HVAC system renovation including supply and return air diffusers and grills and all associated duct work. Refer to attached drawings.
2450 RIVERSIDE AVE, Minneapolis
2450 RIVERSIDE AVE, Minneapolis
HVAC system for partial upgrading including adding 27 VAV boxes and, 2 steam to hot water heat exchanger and all associated piping and duct work and supply and return air diffusers and grills. Refer to attached drawings.
2450 RIVERSIDE AVE #WEST BLDG, Minneapolis
alterations in first floor bridging clinic. sck**** certificate of occupancy required no***** special inspections required no***** const type: 1a occupancy: I2 2015 MSBC******** sprinklered: yes********** architect: anderso
2450 RIVERSIDE AVE, Minneapolis
remodel west wing of 11th floor - NICU. sck*** certificate of occupancy required no special inspections required no const type: 1a occupancy: I2 2015 MSBC sprinklered: yes Tenant: Fairview architect: johansen
2450 RIVERSIDE AVE #EAST BLDG, Minneapolis
minor remodel in 800 pharmacy room M24 - unpacking room. sck***