2402 NE CORAL RIDGE PL, Rochester
Basement finish - 2 bedrooms, family room and bath, electrical roughed in, in lower level. | Basement Finish
2402 NW 7 ST, Rochester
Addition of Filter Press Shelter on east side of plant (Kerry Foods) See also Footing and Foundation permit #R13-0012CB
2402 NW 7 ST, Rochester
Electrical - Addition of Filter Press Shelter on east side of plant (Kerry Foods) See also Footing and Foundation permit #R13-0012CB
2402 NE WILSHIRE LN, Rochester
Alterations - structural re-inforcement; footings 4 x 4 x 12, (2) steel posts, 20KIP rating, storage area below garage floor | Other
2402 NW 7 ST, Rochester
Electrical - relocate R1 packaging line in Dry Blend Packaging Room (NO STRUCTURAL) KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Plumbing (UNDERGROUND ONLY - Footing & Foundation partial phase for an addition of Filter Press Shelter on east side of plant (Kerry Foods)
2402 NW 7 ST, Rochester
Footing & Foundation partial phase for an addition of Filter Press Shelter on east side of plant (Kerry Foods)
2402 NW 7 ST, Rochester
ELECTRICAL - replace MCC Panel Section on 3000A MCC for Arc Flash
2402 NW 7 ST, Rochester
ELECTRICAL - change main service for plant & add KVAR correction capacitor bank
2402 NE CORAL RIDGE PL, Rochester
Electrical - Basement finish - only going to be wired - not doing anything else in basement
2402 NW 7 ST, Rochester
Mechanical - install duct free split inverter - mini split a/c KERRY BIOSCIENCE
2402 NW 7 ST, Rochester
Electrical - cooling tower replacement and control wiring KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Electrical - office/lab RTU replacement after fire KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Electrical - R101 & R102 Blend Tank Automation wiring KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Electrical - Sterilizer in R200 Room KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Electrical - wiring for Boiler #3 KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Electrical - wet blend liquifier KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Replace existing silo pads (Kerry Bio-Science)
2402 NW 7 ST, Rochester
Mechanical - replace rooftop unit damaged by fire KERRY INGREDIENTS
2402 NW 7 ST, Rochester
Gas Piping - replace rooftop unit damaged by fire KERRY INGREDIENTS
2402 NW 7 ST, Rochester
MCC shelter for existing electrical panels (Kerry Bio-Science)
2402 NW 7 ST, Rochester
Replace exsiting facade on north side (Kerry Bio-Science)
2402 NW 7 ST, Rochester
Electrical - install heat trace on chilled water piping KERRY BIO-SCIENCE
2402 NW 7 ST, Rochester
Plumbing - remove existing trench drains - install five (5) floor drains connecting to sanitary sewer in same location.
2402 NW 7 ST, Rochester
Electrical - hooked up two (2) fermentors KERRY BIO-SCIENCE