buildout coffee shop - tenant suite D. aprrox 1800 sq ft. certificate of occupancy required: yes const type: 2a occupancy: A2 2020 MSBC occupant load: 86 sprinklered: yes sac: _5_charges __ met council letter dated _2/11/
ADD INTERIOR PARTITION WALL TO EXISTING OFFICE. NO STRUCTURAL WORK. (JJL) certificate of occupancy required: no special inspections required: no const type: II-A occupancy: B 2020 MSBC occupant load: NO CHANGE s
CONVERSION OF WAREHOUSE TO BUSINESS CENTER buildout approx 5400 sq ft of office space. northeast corner of building. includes a new grouping of men's and women's bathrooms and a family use single user toilet room. certificate of occupancy required:
2 new rooftop units and associated ductwork and grills for new daycare tenant. Gas piping from new meter location to all roof top units. Exhaust fans in all bathrooms. A structural engineer report has been included with the submitted construction document
BLDG1115929 Installing 4 new RTU systems: 110-ton system, 1- 71/2-ton system, and 14-ton system for suites E. and D. Also providing gas piping for the 4 RTU's listed within as well as installing bathroom exhaust for Suite E.
remodel and change of occupancy for new child daycare. certificate of occupancy required yes const type: 2A occupancy: I4 2020 MSBC occupant load: __131___ occupants sprinklered: yes sac: _6_charges met council letter date
Installing rooftop units, energy recovery units, exhaust fans, GRDs and all associated ductwork per approved plans.
Convert portion of existing warehouse into office shell (Suite A) certificate of occupancy required: yes const type: II-A occupancy: B 2020 MSBC occupant load: 41 sprinklered: yes SAC Total Charge: 1.57 To
This project includes the installation of a bathroom group together with plumbing fixtures for a small commercial kitchen. All plumbing shall be installed in accordance with the 2020 Minnesota State Plumbing Code (MSPC), Chapter 4714. A
Change out HVAC system and replace with new HVAC to accommodate space function/layout. BLDG1109725
Install gas piping to (4) kitchen appliance under hood.
Office and deli HVAC systems structural infor is located in projectdox under for drawings, "for refernce folder" BLDG1004753
CONVERT EXISTING WAREHOUSE TO BUSINESS CENTER, COMMUNITY ROOM. (JJL) certificate of occupancy required: yes special inspections required: no const type: IIA occupancy: B, A-3, 2020 MSBC occupant load: 400 sprinklered:
CONVERT WAREHOUSE TO MOSQUE, OFFICES, AND CLASSROOMS. (JJL) CERTIFICATE OF OCCUPANCY REQUIRED. CONST TYPE: IIA NUMBER OF STORIES: 1 STORY WITH BASEMENT OCCUPANCY: A3, S1 2020 MSBC OCCUPANT LOAD: 521 SPRINKLERED: YES FIRE A
Add 2 Bathrooms in Community & Sinks Class Rooms
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.