Replace existing 150A meter socket with new 150A meter socket/disconnect for solar project. Separate permit pulled for solar installation - R24-6434RE
Install a new solar panels system on an existing roof structure. SYSTEM SIZE: 10.00KW (DC), 9.60KW (AC) MODULES: (25) PHILADELPHIA PHENEX SOLAR PS-M108(HCBF)-400 (400W) INVERTER: (25) ENPHASE IQ8H-240-72-2-US RACKING: UNIRAC SOLARMOUNT RAIL | Other
10KW grid tied solar system on top of dwelling. Interconnection will be a line side tap of main electrical service 150A 240V 1 phase to fused PV system. Through 100A PV production meter to 60A Utility AC disconnect, then to 125A IQ Combiner Box. IQ Combiner Box has (3) 20A PV breakers with (1) 15A monitoring breaker. Then run to (25) Enphase IQ8H microinverters and (25) Philadelphia 400W PV modules. Will have 3 total strings installed on roof.
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.