1216 SW 2 ST, Rochester
Fin tube radiation is not heating. Replace with new fin, control valve, ball valves and trap
1216 SW 2 ST, Rochester
LP steam has leak on Mega press fittings. Remove existing piping and install new CI fittings and new steel pipe
1216 SW 2 ST, Rochester
Current back to back bathroom group needs a CO installed on battery of toilets
1216 SW 2 ST, Rochester
Piping to Glycol coils used to capture return air exchange are leaking. Install isolation valves on main piping to find current leak and for future isolation.
1216 SW 2 ST, Rochester
Replacement and relocation of existing commercial dishwasher
1216 SW 2 ST, Rochester
Existing ice/water dispenser and sink needs to be relocated
1216 SW 2 ST, Rochester
Replace existing hot water heating pumps
1216 SW 2 ST, Rochester
Mary Brigh Building-4th Floor-Project ROMB22C0030 Remodel Cath Lab; piping to cooling equipment
1216 SW 2 ST, Rochester
MAYO - FRANCIS BUILDING - 7TH FLOOR ELECTRICAL WORK TO REPLACE VFD AND FS8 SUPPLY FAN MAYO WO 0011246 ADAIR WO W1160
1216 SW 2 ST, Rochester
MAYO - MARY BRIGH BUILDING-2-524 ELECTRIC WORK TO REPLACE VFD ON RETURN FAN MAYO WO 0017396 ADAIR WO W1849
1216 SW 2 ST, Rochester
M0010525 - Scott Knapp Removing MR door at Nasseff Tower- main
1216 SW 2 ST, Rochester
MAYO-GENEROSE BUILDING-GR-3RD FLOOR ELECTRICAL WORK FOR WASTE AND VENT PIPING REPLACEMENT MAYO PROJECT ROGE21C0020 ADAIR JOB 16256
1216 SW 2 ST, Rochester
Mechanical work associated with Installation of new fan coil unit, assist with install of new Price Ceiling. Mayo Number ROET21C0010 - SMH Rm 9 Biplane Harris Job # 81002-02-5080
1216 SW 2 ST, Rochester
Hydronic work associated with the installation of a new fan coil unit. Mayo # ROET21C0010 - SMH Rm 9 Biplane Harris Job # 81002-01-5080
1216 SW 2 ST, Rochester
Plumbing work associated with installation of a new sink. Mayo # ROET21C0010 - SMH Rm 9 Biplane Harris Job # 81002-01-5080
1216 SW 2 ST, Rochester
MAYO - JOSEPH BUILDING - 6-160A: CONFERENCE ROOM ELECTRICAL WORK FOR AUGMENTED REALITY VIRTUAL REALITY SPACE FIT UP MAYO WO 0011076 ADAIR WO W1900
1216 SW 2 ST, Rochester
MAYO - MARY BRIGH BUILDING- GROUND FLOOR 616A ELECTRICAL WORK TO FIT MORE WORKSTATIONS TO MAXIMIZE OFFICE SPACE MAYO WO 0002066 ADAIR WO W1792
1216 SW 2 ST, Rochester
Plumbing work associated with replacing all the existing horizontal domestic water & waste piping on the lower floors (3rd to ground level). ROGE21C0020 GE DHW DCW Harris Job # 56748-5080
1216 SW 2 ST, Rochester
Add VAV box with reheat coil and duct work Mary Brigh Building ground floor room 616A Mayo Number 2088 Harris Job # 56742-26-5080
1216 SW 2 ST, Rochester
Mechanical Work associated with ROMB22C0030 MB Procedure Room Remodel 108 Cardiac Cath Lab. Harris Job # 56750-5080
1216 SW 2 ST, Rochester
LP steam humidifier bar is leaking. Needs new O-rings installed
1216 SW 2 ST, Rochester
2” galv dhw line has pin hole. Replace section of pipe.
1216 SW 2 ST, Rochester
Remove mega press fittings on LP steam and condensate piping
1216 SW 2 ST, Rochester
Remove mega press fittings on LP steam and condensate piping
1216 SW 2 ST, Rochester
Remove mega press fittings on LP steam and condensate piping