Rochester, MN
1216 SW 2 ST, Rochester
Mayo - Francis Building - GR-40 - Electrical work for addition of 208/3 - Mayo WO 0057882 Adair WO W5717 - This work is T&M
1216 SW 2 ST, Rochester
Mayo - Joseph Building - 4-223 - Electrical work for office remodel - Mayo WO 0042487 Adair Wo W5779 - This work is T&M
1216 SW 2 ST, Rochester
Mayo - Joseph Building - 5-175 - Electrical work to remove cold room - Mayo WO 0047271 Adair WO W6400 - This work is T&M
1216 SW 2 ST, Rochester
TEMPERATURE CONTROLS ROFR22C0010
1216 SW 2 ST, Rochester
M0049518 Justin Bernard - Doorways in PITC are too narrow to fit beds through the doorway and units have made due for many years. Due to increase patient safety concerns leadership wants to explore widening doorways in order to be able to transport patient in bed in and out of treatment rooms if needed. Rooms affected are ROMB 5-183B and ROMB 5-183D.
1216 SW 2 ST, Rochester
Controls installation for remodel of Mb04 Cardiac Cath Lab 102
1216 SW 2 ST, Rochester
Replace leaking steam valve on humidifier
1216 SW 2 ST, Rochester
Replace 2 sections of sections of cracked 6" sanitary sewer
1216 SW 2 ST, Rochester
Install new 2 1/2" HWS and HWR for new FCUs connect onto existing CHWS and CHWR to new FCUs
1216 SW 2 ST, Rochester
Replace galv sanitary waste line with NH
1216 SW 2 ST, Rochester
Existing waters being supplied from lower floor, demo existing and pipe new dcw and dhw from floor of use
1216 SW 2 ST, Rochester
Mega Press fitting is leaking replace with threaded fittings
1216 SW 2 ST, Rochester
DHW line for surgical scrub sink is leaking in wall. Remove sink, open wall and repair
1216 SW 2 ST, Rochester
Install backflow 1022 on new coffee maker
1216 SW 2 ST, Rochester
Replace existing CHW control valves with new
1216 SW 2 ST, Rochester
Overflow roof drains are not 2" Higher than primary. Open roof and set to appropriate height
1216 SW 2 ST, Rochester
Floor is pitched away from shower drain, install linear shower drain
1216 SW 2 ST, Rochester
Vent in wall left open to atmosphere on past, get connected to sewer vent stack
1216 SW 2 ST, Rochester
Install chilled water to new FCU and condensate piping
1216 SW 2 ST, Rochester
Install chilled water to FCU and condensate drain
1216 SW 2 ST, Rochester
0044587 New Neurosurgery Workroom/ Hillary Hughes
1216 SW 2 ST, Rochester
0050913 New HIM Consult Workroom/ Hillary Hughes
1216 SW 2 ST, Rochester
Mayo - Francis Building - 01-156 - Electrical work to create new workroom - Mayo WO 0060824 Adair WO W6365 - This work is T&M
1216 SW 2 ST, Rochester
Adding electrical switchgear to get rid of the 2400V that is currently at the Francis building
1216 SW 2 ST, Rochester
Mayo - Old Marian Hall - 01-104,01-120,01-121, 02-128 - See Plans for electrical scope of work - Mayo Project ROXX23E0140 Adair Job 17208 - This work is T&M