Rochester, MN
Rochester, MN
1216 SW 2 ST, Rochester
MAYO - ALFRED BUILDING ELECTRICAL WORK FOR SOILED UTILITY ROOM BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB #16349
1216 SW 2 ST, Rochester
MAYO - DOMITILLA BUILDING ELECTRICAL WORK FOR SOILD UTILITY BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB 16349
1216 SW 2 ST, Rochester
MAYO - FRANCIS BUILDING ELECTRICAL WORK FOR SOILD UTILITY BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB 16349
1216 SW 2 ST, Rochester
MAYO - GENEROSE BUILDING ELECTRICAL WORK FOR SOILD UTILITY BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB 16349
1216 SW 2 ST, Rochester
MAYO - MARY BRIGH BUILDING ELECTRICAL WORK FOR SOILD UTILITY BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB 16349
1216 SW 2 ST, Rochester
MAYO - NASSEFF TOWER BUILDING ELECTRICAL WORK FOR SOILD UTILITY BADGE READERS MAYO PROJECT ROXX21C0460 ADAIR JOB 16349
1216 SW 2 ST, Rochester
MAYO - JOSEPH BUILDING -4-225D: EXAM ROOM ELECTRICAL WORK TO CONVERT EXAM ROOM TO OFFICE MAYO WO 0013947 ADAIR WO W1803
1216 SW 2 ST, Rochester
ROXX21C0460 James Kelly Remodel for SMC Soiled Utility Rooms Badge Readers (Joseph 3rd)
1216 SW 2 ST, Rochester
Install 3” piping, butterfly valves, on CHW piping for corrosion coupon installation.
1216 SW 2 ST, Rochester
Repair 2” DCW high pressure piping, has a pinhole in it
1216 SW 2 ST, Rochester
Demo existing emergency shower/eyewash, and stainless steel sink. Change rough in on sink for new 2 compartment 10” deep sink.
1216 SW 2 ST, Rochester
Multiple problems with DHWR on GE building. Remove existing .50 flow restrictors, install new .33 flow restrictors, ball valves, check valves on multiple DHWR branches.
1216 SW 2 ST, Rochester
Install new emergency drench shower and mixing valve for pharmacy, current location inaccessible
1216 SW 2 ST, Rochester
Mega press fittings leaking on LP steam, remove and new steam piping with new CI fittings
1216 SW 2 ST, Rochester
Installation of new dishwasher and garbage disposal in SIMS Lab. Current Floor Drains do not low enough for lab use. New Floor Drains to be installed at lower height.
1216 SW 2 ST, Rochester
Install new DW&V and domestic waters for sink for new Lactation room
1216 SW 2 ST, Rochester
Repair 2 mega press steam leaks
1216 SW 2 ST, Rochester
Existing DCW riser has a leak
1216 SW 2 ST, Rochester
Steam humidifier bars are leaking. Install new O-rings
1216 SW 2 ST, Rochester
2” DCW line has pinhole leak
1216 SW 2 ST, Rochester
2” non potable water line has pinhole leak at RPZ location. Repipe entire area around device.
1216 SW 2 ST, Rochester
2x1 tee on non potable water line has pinhole
1216 SW 2 ST, Rochester
Wall hung toilet has broken barrel and is leaking. Install new barrel and reinstall existing toilet
1216 SW 2 ST, Rochester
Section of 3” galv Domestic soft cold water has leak. Install new galv piping and new Vic couplings
1216 SW 2 ST, Rochester
Replace 4” sanitary sewer piping due to leak
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.