1216 SW 2 ST, Rochester
Mechanical (demo, ductwork, VAV & GRD) - PMR Wound Management Bid Pack 2, Phase II (SMH - Domitilla 1st - 7R090541) See Permit #R12-0309CB for Bid Pack 1, Phase II
1216 SW 2 ST, Rochester
PLUMBING - install utilities for medivator test station SMH - MARY BRIGH 2-730A TOILET / WO307449
1216 SW 2 ST, Rochester
PLUMBING - fan coil supplying this procedure room is undersized & cannot keep up w/the heating load; SMH - DOMITILLA 5-266 PATIENT ROOM / WO304912
1216 SW 2 ST, Rochester
PLUMBING - water leak repair from the floor drain; clean & restore SMH - FRANCIS 8T-1 EQUIPMENT ROOM / WO308679
1216 SW 2 ST, Rochester
PLUMBING - redesign porter room to accommodate cleaning of TEE probes SMH - MARY BRIGH 4-670 CUSTODIAL ROOM / WO305785
1216 SW 2 ST, Rochester
PLUMBING - (rph) rotted out drain line under dietary pantry area possible cabinet replacement repair rotted drain line for now; SMH - FRANCIS 1-135 TRAY SERVICE/PANTRY / WO308717
1216 SW 2 ST, Rochester
PLUMBING - dietary sewer upgrad/ replace the north bound double wye 4" sanitary sewer along the west FND wall; SMH - FRANCIS BA-20 EQUIPMENT ROOM / WO308769
1216 SW 2 ST, Rochester
PLUMBING - (RPH) conveyor belt clean out located near ice machine & conveyor on ground, needs replacing; SMH - FRANCIS BA-20 EQUIPMENT ROOM / WO308539
1216 SW 2 ST, Rochester
PLUMBING - rotted drain line these lines serve main kitchen hot wells SMH - FRANCIS GR-9 STORAGE / WO308643
1216 SW 2 ST, Rochester
PLUMBING - in basement drain is rotted & during snaking it has busted open, banaid in place need 4" by 5" Y replaced & length of piping; SMH - FRANCIS BA-20 EQUIPMENT ROOM / WO308642
1216 SW 2 ST, Rochester
PLUMBING - replace the existing 8" HP water main w/new 8" Sch-10 stainless steel pipe; add an 8" isolation valve w/2-2" flush & drain valves & 2-3/4" air vents. SMH - MARY BRIGH GR-505 EQUIPMENT ROOM / WO307142
1216 SW 2 ST, Rochester
PLUMBING - replace 4 chilled water service valves; insulate, label document, & valve tag the entire repair area; SMH - MARY BRIGH 2-730 EQUIPMENT ROOM / WO308654
1216 SW 2 ST, Rochester
PLUMBING - replace leaking steam valves on HX 5 SMH - MARY BRIGH 9-502 EQUIPMENT ROOM / WO308430
1216 SW 2 ST, Rochester
PLUMBING - install utilities for medivator test station SMH - LAUNDRY BUILDING MN-650 DOCK / WO308413
1216 SW 2 ST, Rochester
PLUMBING - steam kettle piping clean up; remove all domestic water dead legs; remove the steam to sanitary sewer drain line; replace all steam & condesate valves SMH - FRANCIS MN-37 KITCHEN / WO308178
1216 SW 2 ST, Rochester
PLUMBING - urgent low pressure steam request; install a 8" LP steam shut off valve in the south bound main south of the south LP steam header; SMH - FRANCIS BA-20 EQUIPMENT ROOM / WO308444
1216 SW 2 ST, Rochester
PLUMBING - repair the leaking rain leader, insulate, label & document the repair area SMH - GENEROSE 1-151 MORSE LECTURE HALL / WO307561
1216 SW 2 ST, Rochester
PLUMBING - repl the exhausted 1 1/2" sanitary sewer in the ceiling space of rooms 225A, 229 & 224A SMH - JOSEPH 6-229 PROCEDURE-MEDICAL IMAGING / WO307643
1216 SW 2 ST, Rochester
PLUMBING - patient room shower is currently piped backwards, repair, insulate, labe, document, and valve tag the repiar area SMH - DOMITILLA 5-343 PATIENT ROOM - SEMI PRIVATE / WO307640
1216 SW 2 ST, Rochester
PLUMBING - assist SMH-SPL w/our campus wide steam trap program
1216 SW 2 ST, Rochester
Electircal (infill/support Johnson Control Low Voltage) - Edith Graham Courtyard - Bid Pkg 5 - (St Marys Hospital - Mary Brigh - 7R100070) See also Edith Graham Courtyard - Bid Pkg 2 - R12-0050CB and Micro-piers - R12-0021CB
1216 SW 2 ST, Rochester
Electrical - 3X CT scanner replacement in room M-645 (SMH - MB Main - 7R120040) PO 602664-3-910
1216 SW 2 ST, Rochester
Admissions ACO relocation (SMH- Mary Brigh, GR - 7R111180) See also Generrose R12-0336CB
1216 SW 2 ST, Rochester
Cardiology Procedure room 4-647 renovation (SMH - MB 4th - 7R100310)
1216 SW 2 ST, Rochester
Electrical - Cardiology Procedure room 4-647 renovation (SMH - MB 4th - 7R100310) PO 602652-4-910-e