PULLFIRST[THE RECORD]
Permit / Ramsey← Search
#RA058566

Building

6601 153rd Ct NW, Ramsey

IssuedAug 5, 2024
StatusUnknown
Value$10,000
Inspections7
Scope of work

Alteration

Location context
Parcel223225410004
Coordinates45.24794, -93.43481
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedAug 5, 2024
IssuedAug 5, 2024
Inspection record
Inspections7
Passed6
Failed0
  1. Oct 29, 2024

    Framing/Sheathing /Rim Joist

    Pass

    InspectorDean Becker

    Footing passed.
  2. Oct 29, 2024

    Final

    Pass

    InspectorDean Becker

    All corrections complete.
  3. Oct 24, 2024

    Footing

    Pass

    InspectorDean Becker

    Verified proper size and depth of the 2 additional footings.
  4. Aug 12, 2024

    Framing/Sheathing /Rim Joist

    Partial Pass

    InspectorNick Gilliland

    All framing passes. Footing must pass.
  5. Aug 12, 2024

    Final

    Partial Pass

    InspectorNick Gilliland

    Footings must pass.
  6. Aug 8, 2024

    Framing/Sheathing /Rim Joist

    Notes

    InspectorNick Gilliland

    Inspected roof framing, beams, and posts. Verified beams sitting on exterior wall. Missing outer front posts. Done at footing inspection.
  7. Aug 8, 2024

    Footing

    Partial Pass

    InspectorNick Gilliland

    Front 3 footings measured 20" at base Unable to verify middle footing.

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.