PULLFIRST[THE RECORD]
Permit / Ramsey← Search
#RA059121

Building

16430 Quartz St NW DUP, Ramsey

IssuedOct 28, 2024
StatusUnknown
Value$256,400
Inspections34
Scope of work

New, New Dwelling

Location context
Parcel163225110020
Coordinates45.26906, -93.45324
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedOct 24, 2024
IssuedOct 28, 2024
Inspection record
Inspections34
Passed28
Failed0
  1. Jun 13, 2025

    Landscaping Final

    Pass

    InspectorChris Anderson

    Asphalt d/w in, sod in, 1 tree planted and existing front yard tree satisfies the 2nd tree requirement.
  2. Jun 3, 2025

    Topsoil

    Pass

    InspectorJosh Osen

    Per email from Josh Osen on 6/3/25; passed
  3. Mar 28, 2025

    Final Building

    Pass

    InspectorEric Hoffman

    Engineer letter with property file.
  4. Mar 28, 2025

    Framing

    Pass

    InspectorEric Hoffman

  5. Mar 27, 2025

    Final Building

    Partial Pass

    InspectorEric Hoffman

    Corrections from 3/21/25 are completed except 1 item: 1. Engineered drawing did not match the site specific observations. The engineer used was not the original designer on record and the new engineer needs to provide a letter including the review of the entire wall bracing with site specific alternative methods as approved. Including threaded re-rod and block construction. Note: No glass doors/panels installed in shower or tub compartments. (not required) Note: No A/C installed (not required)
  6. Mar 27, 2025

    Well Affidavit

    Pass

    InspectorAlejandra Sanchez

    Received Well and Boring Construction Record
  7. Mar 26, 2025

    Water Test Results

    Pass

    InspectorAlejandra Sanchez

    Received Water Analysis Report.
  8. Mar 24, 2025

    Final Building

    Notes

    InspectorEric Hoffman

    Spoke with mechanical contractor to verify the HRV does not need external damper on exhaust. He (Curt) plans on installing 1/4" galv hardware cloth to bath fan exhaust behind the damper. This would be approved.
  9. Mar 21, 2025

    Final Building

    Orders Issued

    InspectorEric Hoffman

    -Needs Water test document -Needs Well Affidavit -Needs Septic Inspection Report with tanks as passed with alarm verification -Needs ground breaker -Needs HRV damper on exhaust hood or documention otherwise -Needs Screen in bath fan hood on rear wall only -Needs safety glass for tub window and shower door -No A/C installed
  10. Mar 21, 2025

    Framing

    Partial Pass

    InspectorEric Hoffman

    Correction notes from 1/2/25 still need verification. Not provided at building final.
  11. Mar 21, 2025

    Rough Plumbing

    Pass

    InspectorEric Hoffman

  12. Mar 21, 2025

    Heating Final

    Pass

    InspectorEric Hoffman

  13. Mar 21, 2025

    Plumbing Final

    Pass

    InspectorEric Hoffman

  14. Mar 6, 2025

    Plumbing Final

    Partial Pass

    InspectorDean Becker

    Manometer test included. Verify Hot & Cold running water at the building final inspection.
  15. Mar 6, 2025

    Backflow Preventer

    Pass

    InspectorDean Becker

  16. Mar 3, 2025

    Framing

    Partial Pass

    InspectorEric Hoffman

    All floor joists and framing in basement okay. Correction from 1/2/25 for portal frame hold-downs still need verification.
  17. Mar 3, 2025

    Heating Final

    Partial Pass

    InspectorEric Hoffman

    Verify proper operation of the exhaust fans at the building final inspection.
  18. Mar 3, 2025

    Rough Heating

    Pass

    InspectorEric Hoffman

    Lower level rough-in complete.
  19. Feb 19, 2025

    Plumbing Final

    Canceled

    InspectorDave Rankin

  20. Feb 18, 2025

    Lath

    Pass

    InspectorEric Hoffman

  21. Jan 6, 2025

    Floor Poly

    Pass

    InspectorDean Becker

    Contractor responsible to seal hole in vapor barrier at the base of the stairs prior to pouring concrete. Radon pulled from drain-tile.
  22. Jan 2, 2025

    Rough Heating

    Partial Pass

    InspectorEric Hoffman

    All appeared OK except basement return branches for future finish not ran and were stubbed out in utility room. Framing in basement only will need to be re inspected after returns are ran.
  23. Jan 2, 2025

    Framing

    Partial Pass

    InspectorEric Hoffman

    1. Basement heating returns not installed and floor trusses will need to be inspected once complete. (told justin not to cover ceiling in bsmt) 2. Portal frame hold-downs in garage need engineering for repairs still. ***orders from 12/26/24 otherwise appeared OK***
  24. Jan 2, 2025

    Insulation

    Pass

    InspectorEric Hoffman

  25. Jan 2, 2025

    Floor Poly

    Pass

    InspectorEric Hoffman

Show 9 earlier inspections
  1. Dec 31, 2024

    Underground Rough In

    Pass

    InspectorNick Gilliland

    Air pressure test included.
  2. Dec 30, 2024

    Rough Heating

    Not Ready

    InspectorBrant Schreder

    not fully complete, can be verified with framing corrections at future inspection.
  3. Dec 26, 2024

    Framing

    Orders Issued

    InspectorNick Gilliland

    1. Galvanized Staples were used in treated plate, Staples required to be of stainless steel or Galvanized nails per R317.3.1. 2. Bracing in floor trusses were cut out by heating contractor and need to be replaced 3. Header in bedroom #2 required to be a 2ply 9.5 LVL per plan S2 4. Basement patio door not secured at top and missing flashing tape. 5. all seames in WRB to be sealed with approved Tape including vertical seams. 6. STHD 14 straps are not approved for uplift into the concrete garage floor. 1/2" anchor bolts were installed in place of the approved 5/8"bolts in the garage portal wall per page S5 detail D8. Engineered repair required. 7. Plumbing underground and Floor poly must pass. *OK to insulate as long as all repairs are visible*
  4. Dec 26, 2024

    Rough Heating

    Partial Pass

    InspectorNick Gilliland

    All seams in ductwork to be sealed including the adjustable elbows per code.
  5. Dec 17, 2024

    Rough Plumbing

    Partial Pass

    InspectorDean Becker

    Included air test for all except kitchen which will be tested with the underground air test. Radon to be pulled from the drain-tile. Radon pipe is insulated in the attic.
  6. Dec 17, 2024

    Footing

    Pass

    InspectorDean Becker

    Address numbers are posted.
  7. Nov 19, 2024

    Foundation

    Pass

    InspectorDean Becker

    Contractor responsible to ensure slip sheet is in place prior to backfilling due to wind issues.
  8. Nov 13, 2024

    Footing

    Partial Pass

    InspectorBrant Schreder

    Address numbers shall be posted and visible for the duration of the project.
  9. Nov 6, 2024

    Footing

    Not Ready

    InspectorDean Becker

    No address is posted.