#RA059102

Building

5727 164th Ave NW, Ramsey

IssuedOct 31, 2024
StatusUnknown
Value$507,300
Inspections32
Scope of work

New, New Dwelling

Location context
Parcel143225110030
Coordinates45.26786, -93.41133
Loading map…
199 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedOct 30, 2024
IssuedOct 31, 2024
Inspection record
Inspections32
Passed24
Failed0
  1. Sep 29, 2025

    Topsoil

    Pass

    InspectorAaron Madsen

    Per email from Aaron Madsen on 9/29/25; passed
  2. Sep 26, 2025

    Landscaping Final

    Pass

    InspectorChris Anderson

    Erosion blankets were installed next to driveway. Yard is more than 90% established.
  3. Sep 24, 2025

    Landscaping Final

    Partial Pass

    InspectorChris Anderson

    Seed has established throughout the yard and existing trees satisfy the planting requirement. There is an area just north of driveway that is a steep slope of bare, exposed soil. I let the home owner know that they need to get an erosion blanket down so that during rains, there is not a bunch of soil spilling out onto the public road. She was going to let me know when this was completed.
  4. Jun 25, 2025

    Topsoil

    Not approved

    InspectorJake Hoel

    Per email from Jake Hoel on 6/25/25, mostly sand; failed
  5. Jun 12, 2025

    Final Building

    Pass

    InspectorDave Rankin

    No topsoil or landscaping. Driveway complete Septic permit still open
  6. Jun 12, 2025

    Lath

    Not Required

    InspectorDave Rankin

  7. Jun 11, 2025

    Well Affidavit

    Pass

    InspectorAlejandra Sanchez

    Received Wall and boring construction record
  8. Jun 11, 2025

    Water Test Results

    Pass

    InspectorAlejandra Sanchez

    Received Drinking water laboratory test report
  9. Jun 10, 2025

    Final Building

    Orders Issued

    InspectorDave Rankin

    Roof above front window not installed. Window to the right of fireplace does not close/broken Smoke and CO's covers must be removed throughout Septic not inspected or closed in our system No lath inspection No well certification paperwork
  10. Jun 9, 2025

    Backflow Preventer

    Pass

    InspectorDave Rankin

  11. Jun 9, 2025

    Final Building

    Orders Issued

    InspectorDave Rankin

    Roof above front window not installed. Basement window not trimmed out Window to the right of fireplace does not close/broken Smoke and CO's covers must be removed throughout Stairs in garage not correct Septic not inspected or closed in our system No lath inspection No well certification paperwork
  12. Jun 9, 2025

    Fireplace Final

    Pass

    InspectorDave Rankin

  13. Jun 2, 2025

    Plumbing Final

    Pass

    InspectorDean Becker

    Includes manometer test. Basement bar lav not going to be installed for the building final inspection (on back order).
  14. May 7, 2025

    Heating Final

    Pass

    InspectorDean Becker

    Included air test.
  15. Mar 24, 2025

    Insulation

    Pass

    InspectorEric Hoffman

    Remaining completed. Contractor to ensure roof jack for radon gets installed prior to insulating attic.
  16. Mar 24, 2025

    Rough Heating

    Pass

    InspectorDean Becker

    All corrections are complete.
  17. Mar 20, 2025

    Insulation

    Partial Pass

    InspectorEric Hoffman

    Rim space spray foam only, OK
  18. Mar 19, 2025

    Fireplace Rough In

    Pass

    InspectorDave Rankin

  19. Mar 19, 2025

    Framing/Sheathing /Rim Joist

    Pass

    InspectorDean Becker

    Truss screws are verified.
  20. Mar 17, 2025

    Rough Heating

    Partial Pass

    InspectorDean Becker

    Dryer exhaust duct still not insulated on the hallway side. All ductwork through top plate must have protective straps/plates installed. Can be verified at the insulation inspection.
  21. Mar 17, 2025

    Heating Final

    Not Ready

    InspectorDean Becker

    Scheduled by accident by the contractor.
  22. Mar 17, 2025

    Plumbing Final

    Not Ready

    InspectorDean Becker

    Scheduled by accident by the contractor. Shower head lowered to conditioned space.
  23. Mar 17, 2025

    Framing/Sheathing /Rim Joist

    Orders Issued

    InspectorDean Becker

    Gold truss screws replaced with silver screws - contractor to submit fastener specifications for review. Once specifications are reviewed and approved this can be passed without an additional site visit.
  24. Mar 14, 2025

    Framing/Sheathing /Rim Joist

    Orders Issued

    InspectorDave Rankin

    Gold truss screws are incorrect. Provide documentation or install correct screws.
  25. Feb 26, 2025

    Rough Plumbing

    Pass

    InspectorEric Hoffman

    pressure tested. verify rain head in upper bath shower is within conditioned space. plumbing installer informed contractor that they need to drop down the ceiling to accomplish this. Plumber installed blocking to lower installed head.
Show 7 earlier inspections
  1. Feb 26, 2025

    Rough Heating

    Partial Pass

    InspectorEric Hoffman

    Observed breaks in insulation and vapor barrier on ducting doing through 2x4 wall coming from unconditioned space. Spoke with contractor to ensure the opening in the top plates is completely sealed with spray foam in an effort to keep continuity for the vapor barrier/insulation requirements. The basement also needed the ducting joints sealed, remaining house appeared OK. Check for duct sealing and top plates in upper level at framing for compliance.
  2. Feb 5, 2025

    Floor Poly

    Pass

    InspectorDean Becker

    Address to be posted per R319.1. Contractor responsible to protect all plumbing penetrations per MN Plumbing code 312.2 as discussed with Cory while on site.
  3. Jan 31, 2025

    Underground Rough In

    Pass

    InspectorThomas Knight

    included air test
  4. Dec 2, 2024

    Foundation

    Pass

    InspectorTracy Davis

    Viewed pictures on site for waterproofing.
  5. Nov 25, 2024

    Poured Wall

    Pass

    InspectorDean Becker

    All items corrected.
  6. Nov 19, 2024

    Poured Wall

    Orders Issued

    InspectorDean Becker

    Corrections: (1) Contractor to establish connection between the garage and house ICF's. (2) The garage is wider than the reviewed plan (26' on plan) back wall is about 30'. Install footing/poured wall per reviewed plan or submit updated plans. (3) No horizontal rebar installed at time of inspection. Contractor to pour house at own risk.
  7. Nov 14, 2024

    Footing

    Pass

    InspectorNick Gilliland

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.