Permit / Ramsey← Search
#RA061526Building
14047 Azurite St NW, Ramsey
IssuedSep 15, 2025
StatusUnknown
Value$50,000
Inspections13
Scope of work
Alteration, Building
Location context
Loading map…
198 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedSep 10, 2025
IssuedSep 15, 2025
Inspection record
Inspections13
Passed9
Failed0
- Jan 6, 2026
Final Building
Partial PassInspectorDave Rankin
Unit 5 - Not complete. Mechanical permits still required for unit heaters and added gas lines.
- Dec 31, 2025
Final Building
Orders IssuedInspectorDave Rankin
Unit 1 - ok Unit 2 - Move camper out of accessible parking Unit 3 - OK Unit 4 - Insulation required above heater @ entrance. Seal all penetrations Unit 5 - Not ready, mechanical permit required, electrical not ready, Sheet rock still needs to be installed. unit 6 - Mechanical permit required for heater
- Dec 31, 2025
Fire Wall
PassInspectorDave Rankin
- Dec 31, 2025
Framing
PassInspectorDave Rankin
- Dec 31, 2025
Siding Final
PassInspectorDave Rankin
- Nov 18, 2025
Fire Wall
Orders IssuedInspectorDave Rankin
North building has 2 hour wall. Updated plans changes to 3 hour wall.
- Nov 4, 2025
Siding Final
Orders IssuedInspectorDave Rankin
Flashing required at corners of OHD's. Seal all penetrations
- Nov 4, 2025
Fire Wall
Partial PassInspectorDave Rankin
NE unit below ceiling firewall ok. Must inspect above ceiling
- Oct 21, 2025
Fire Wall
Partial PassInspectorDave Rankin
Unit 32 only
- Oct 16, 2025
Fire Wall
Orders IssuedInspectorDave Rankin
Orange spray foam not allowed. Electrical boxes not covered. Contractor states the engineer is drawing up plans for 2 hour fire wall by electrical boxes. 4' section from concrete to roof line.
- Oct 6, 2025
Fire Wall
Partial PassInspectorDave Rankin
Unit 32 only
- Sep 25, 2025
Insulation
Partial PassInspectorDave Rankin
1st unit on south end of pole barn
- Sep 25, 2025
Water-Resistive Barrier
PassInspectorDave Rankin
Pole barn on only
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.