8421 156th La NW, Ramsey
IssuedSep 25, 2025
StatusUnknown
Value$65,000
Inspections8
Scope of work
Remodel
Location context
Loading map…
198 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedSep 25, 2025
IssuedSep 25, 2025
Inspection record
Inspections8
Passed5
Failed0
- Jan 9, 2026
Other
PassInspectorThomas Knight
Head clearance in bathroom is below 6'4 inches. Ductwork was existing. Inspectors offered multiple solutions for a less hazardous condition such as moving the bathroom to a different location at time of rough in, Re-routing ductwork. Contractor chose to cover the ductwork without any change.
- Jan 7, 2026
Final
Orders IssuedInspectorThomas Knight
Missing Smoke and Carbon Monoxide detectors on the main floor. Handrail to basement is not code compliant. Pull permit for mechanical work. Electrical is not signed off. Head clearance in bathroom is below 6'4 inches. Ductwork was existing. Inspectors offered multiple solutions for a less hazardous condition such as moving the bathroom to a different location at time of rough in, Re-routing ductwork. Contractor chose to cover the ductwork without any change.
- Jan 7, 2026
Framing/Sheathing /Rim Joist
PassInspectorThomas Knight
Head clearance in bathroom is below 6'4 inches. Ductwork was existing. Inspectors offered multiple solutions for a less hazardous condition such as moving the bathroom to a different location at time of rough in, Re-routing ductwork. Contractor chose to cover the ductwork without any change.
- Jan 7, 2026
Insulation
PassInspectorThomas Knight
Head clearance in bathroom is below 6'4 inches. Ductwork was existing. Inspectors offered multiple solutions for a less hazardous condition such as moving the bathroom to a different location at time of rough in, Re-routing ductwork. Contractor chose to cover the ductwork without any change.
- Nov 12, 2025
Other
Orders IssuedInspectorJosh Guin
Site visit required by Building Official to determine if exception may be allowed.
- Nov 10, 2025
Framing/Sheathing /Rim Joist
Partial PassInspectorThomas Knight
Per josh Guin all framing was Okay with the exception of head clearance concern
- Nov 10, 2025
Insulation
Partial PassInspectorJosh Guin
Outside of bathroom ok to sheetrock
- Oct 16, 2025
Other
Orders IssuedInspectorDave Rankin
Mechanical permit required. - Trunk line in bathroom measures 6' 3/4" before floor is in and ceiling finished. Butts up against tub. Must not be less than 6'4" finished. - single wall vent in garage penetrates firewall. not allowed. - Double hung window in basement bedroom must meet emergency and rescue opening requirements
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.