PULLFIRST[THE RECORD]
Permit / Ramsey← Search
#RA062227

Building

8841 170th Ct NW, Ramsey

IssuedOct 7, 2025
StatusUnknown
Value$665,661
Inspections15
Scope of work

New, New Dwelling

Location context
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedOct 7, 2025
IssuedOct 7, 2025
Inspection record
Inspections15
Passed13
Failed0
  1. Jan 21, 2026

    Insulation

    Orders Issued

    InspectorDave Rankin

    Trunk lines must be insulated continuously Chutes missing in attic Mother in law suite - corner not sprayed and no insulation various areas throughout spray foam cracking due to application when too cold
  2. Jan 21, 2026

    Framing/Sheathing /Rim Joist

    Pass

    InspectorDave Rankin

  3. Jan 13, 2026

    Framing/Sheathing /Rim Joist

    Orders Issued

    InspectorDave Rankin

    - Anchor bolts missing at door way to mother in law suite - HDU's missing in master bedroom North wall, 2 required in each corner in sitting room adjacent to dining room, 2 in party room west wall facing patio - Plumbing nail plates required on bottom plates in bar/bath area and bathrooms in NE corner by party room - Framing for future fire place has been observed. Separate fireplace permits required - OK to insulate
  4. Jan 13, 2026

    Rough Heating

    Pass

    InspectorDave Rankin

    Manometer required at final
  5. Jan 13, 2026

    Rough Plumbing

    Pass

    InspectorDave Rankin

  6. Dec 2, 2025

    Floor Poly

    Pass

    InspectorDave Rankin

    in floor heat with insulation. 30 psi
  7. Nov 25, 2025

    Deck Footing

    Pass

    InspectorDave Rankin

  8. Nov 25, 2025

    Floor Poly

    Pass

    InspectorDave Rankin

  9. Oct 27, 2025

    Underground Rough In

    Pass

    InspectorDave Rankin

  10. Oct 20, 2025

    Poured Wall

    Pass

    InspectorThomas Knight

    Affidavit provided and is in property file
  11. Oct 20, 2025

    Foundation

    Pass

    InspectorThomas Knight

    Affidavit provided and is in property file
  12. Oct 14, 2025

    Foundation

    Partial Pass

    InspectorMichael Yoakam

    exterior foam insulation not complete at time of inspection. Contractor to send pictures verifying last section complete, along with pictures of foam sealant at corners and seams
  13. Oct 13, 2025

    Poured Wall

    Partial Pass

    InspectorDean Becker

    All poured wall inspections are complete. Engineering to be submitted for cold joint poured wall installation per Thomas.
  14. Oct 10, 2025

    Poured Wall

    Partial Pass

    InspectorMichael Yoakam

    1) Partial pour due to size of project. Contractor to install a keyway separation at point of termination for pour #1. Additional pour being done week of 10-13-2025. Rebar per plan confirmed installed 16" on center for ALL footing area receiving poured wall
  15. Oct 9, 2025

    Footing

    Pass

    InspectorDean Becker

    Contractor responsible to remove a couple of roots as discussed while onsite.

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.