PULLFIRST[THE RECORD]
Permit / Ramsey← Search
#RA064103

Electrical

8031 176th La NW, Ramsey

IssuedNov 17, 2025
StatusUnknown
ValueNot reported
Inspections2
Scope of work

Alteration

Location context
Parcel053225410006
Coordinates45.29101, -93.47140
Loading map…
198 nearby
This permitNearby
Fees & payments
Total fees$124.9
Timeline
ApprovedNov 18, 2025
IssuedNov 17, 2025
Inspection record
Inspections2
Passed2
Failed0
  1. Feb 18, 2026

    Final

    Pass

    InspectorAndrew Sloth

  2. Jan 13, 2026

    Final

    Partial Pass

    InspectorAndrew Sloth

    Fail Needs bond bushing on nipple for unfussd wires Needs handle ties on multi wire branch circuits. Verify duct seal in back of meter Bond around water softener Strap wire above and below panel. Needs to install scab board above panel for proper strapping and clearance from face of nailer/stud (1 1/4”)