PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV118727

Building

1433 Angelo Dr, Golden Valley

IssuedMay 20, 2024
StatusUnknown
Value$175,000
Inspections10
Scope of work

Addition, Single story home shop addition, 1175sf.

Location context
Parcel1802924330005
Coordinates44.99400, -93.34418
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$980.53
Total paid$980.53
Timeline
ApprovedMay 17, 2024
IssuedMay 20, 2024
Inspection record
Inspections10
Passed10
Failed0
  1. Aug 19, 2025

    Insulation-Roof Insulation

    Completed

    InspectorBrian Stemwedel

    7.5" Polyiso insulation above deck. with a structural slope
  2. Aug 19, 2025

    Final

    Completed

    InspectorBrian Stemwedel

  3. Nov 21, 2024

    Insulation

    Completed

    InspectorMike Lockman

    CC spray foam in 2x6 exterior walls and in boiler room ceiling constructed w/ 2x10 nominal lumber. Foam in ceiling is approximately 7-8" thick
  4. Nov 21, 2024

    Insulation-Roof Insulation

    Completed in Future.

    InspectorMike Lockman

    Contractor reports that the flat roof is insulated with 7" of rigid foam. Roof all covered - could not verify. Photos will be acceptable
  5. Oct 15, 2024

    Submit Pictures of House Wrap

    Completed

    InspectorBrian Stemwedel

    verified during framing insp
  6. Oct 15, 2024

    Framing

    Completed

    InspectorBrian Stemwedel

    ISCWAP
  7. Jul 23, 2024

    Foundation Insulation

    Completed

    InspectorBrian Stemwedel

    Draining type foundation insulation (R10)
  8. Jul 23, 2024

    Foundation Waterproofing

    Completed

    InspectorBrian Stemwedel

    Spray applied asphalt
  9. Jul 15, 2024

    Poured Wall

    Completed

    InspectorMike Lockman

    Wall SCWAP. #4 Vertical bar @ 18" OC and #4 bar horizontally @ 12" OC
  10. Jul 10, 2024

    Footing

    Completed

    InspectorBrian Stemwedel

    20x10 strip footings per plans w/ (2) #4's cont. doweled into ex. fnd.

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.