PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV118159

Building

518 Ardmore Dr, Golden Valley

IssuedJun 26, 2024
StatusUnknown
Value$300,000
Inspections24
Scope of work

New, New Home

Location context
Parcel1902924410152
Coordinates44.98289, -93.33368
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$1,468.03
Total paid$1,468.03
Timeline
ApprovedJun 26, 2024
IssuedJun 26, 2024
Inspection record
Inspections24
Passed24
Failed0
  1. Jul 25, 2025

    As-Built Survey

    Completed

    InspectorDan Anderson

  2. Jul 25, 2025

    Final

    Completed

    InspectorDan Anderson

  3. Jul 24, 2025

    Final

    Completed in Future.

    InspectorBret Eggers

    Everything completed except As Built
  4. Jul 24, 2025

    Blower Door Test

    Completed

    InspectorBret Eggers

    Final result 1.68 ACH50
  5. Jul 10, 2025

    I & I Inspection

    Completed

    InspectorScott Johnson

  6. Jun 17, 2025

    Final

    Completed in Future.

    InspectorBret Eggers

    1) I and I 2) Blower Door 3 As built 4) Draft stop floor cavity above wall between utility room and hallway 5) Repair door to utility room, does not close fully 6) Combustion air required in utility room
  7. Jun 17, 2025

    Blower Door Test

    Completed in Future.

    InspectorBret Eggers

  8. Jun 17, 2025

    I & I Inspection

    Completed in Future.

    InspectorBret Eggers

  9. Jun 17, 2025

    Verify Electrical Final

    Completed

    InspectorMike Lockman

    Verified final sticker inside electrical panel
  10. Jun 17, 2025

    Radon Control

    Completed

    InspectorMike Lockman

    Passive system installed & labeled
  11. Jun 17, 2025

    As-Built Survey

    Completed in Future.

    InspectorBret Eggers

  12. Jun 16, 2025

    Submit Pictures of Ice & Water Shield

    Completed

    InspectorBrian Stemwedel

    pictures emailed show compliant I & W on a simple gable roof. *NOTE: Could not verify ventilation
  13. Jun 16, 2025

    Submit Pictures of House Wrap

    Completed

    InspectorBrian Stemwedel

    Pictures emailed Zipwall system, pictures show joints sealed with correct product approved
  14. Jun 13, 2025

    Submit Pictures of Ice & Water Shield

    Completed

    InspectorMike Lockman

    Photos sent via email
  15. Jun 13, 2025

    Submit Pictures of House Wrap

    Completed

    InspectorMike Lockman

    Photos submitted via email. Contractor installed ZIP system wall sheathing
  16. Jun 13, 2025

    Energy Code-Lighting Schedule Form

    Completed

    InspectorMike Lockman

    Document submitted via email. Uploaded into LF
  17. May 29, 2025

    Other - Deck Footing

    Completed

    InspectorBret Eggers

  18. Dec 10, 2024

    Insulation

    Completed

    InspectorBret Eggers

  19. Dec 4, 2024

    Framing

    Completed

    InspectorBret Eggers

  20. Aug 30, 2024

    Drain Tile

    Completed

    InspectorBrian Stemwedel

    Checked with Fnd waterproofing. DT set in river rock and covered w/ fabric
  21. Aug 30, 2024

    Foundation Waterproofing

    Completed

    InspectorBrian Stemwedel

    emulsified asphalt. noted over top of fnd. wall
  22. Aug 30, 2024

    Foundation Insulation

    Completed

    InspectorBrian Stemwedel

    2" rigid (non draining) foam insulation. (***note, ND rigid requires slip sheet below grade)
  23. Aug 13, 2024

    Poured Wall

    Completed

    InspectorMike Lockman

    Poured foundation walls per plan. Reinforcement ISCWAP
  24. Aug 8, 2024

    Footing

    Completed

    InspectorBrian Stemwedel

    (2) mats of rebar in spread footings per engineering and ISCWAP

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.