  1. Mar 30, 2026

    Final

    Partial Pass

    InspectorDean Becker

    Correction (1) is complete from 3/24/2026. Correction: (2) Lower level spray foam shall be covered with an approved Fire-retardant product or an intumescent coating be applied.
  2. Mar 24, 2026

    Final

    Orders Issued

    InspectorDean Becker

    Corrections: (1) The insulation & vapor barrier must be covered with an approved fire-resistant product or install a fire-retardant vapor barrier in place of the vapor barrier that is installed presently. Pictures are okay for re-inspection - dbecker@cityof ramsey.com. (2) Lower level spray foam shall be covered with an approved fire-resistant product or a Intumescent coating be applied.
  3. Mar 24, 2026

    Insulation

    Pass

    InspectorDean Becker

  4. Mar 18, 2026

    Framing/Sheathing /Rim Joist

    Pass

    InspectorThomas Knight

    Passed based on pictures applicant showed.
  5. Mar 2, 2026

    Framing/Sheathing /Rim Joist

    Orders Issued

    InspectorDean Becker

    Corrections: (1) (2)jack studs and (2)king studs are required per Table 602.7.5 and must carry down to the foundation.