Permit / Golden Valley← Search
#GV120644Building
1439 Alpine Pass, Golden Valley
IssuedAug 7, 2024
StatusUnknown
Value$65,000
Inspections13
Scope of work
Addition, 2 story addition 6 ft extension, crawlspace, dining, office, sep. LL bath refresh
Location context
Parcel3002924410058
Coordinates44.96793, -93.33251
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$521.04
Total paid$521.04
Timeline
ApprovedJul 26, 2024
IssuedAug 7, 2024
Inspection record
Inspections13
Passed12
Failed0
- Nov 21, 2024
Insulation
CompletedInspectorMike Lockman
Insulation report for attic received via email from GC & uploaded into LF
- Nov 21, 2024
Final
CompletedInspectorMike Lockman
- Nov 19, 2024
Other - Smoke & Carbon Alarm at Time of Final
CompletedInspectorMike Lockman
Smoke and CO alarms compliant thru out
- Nov 15, 2024
Submit Pictures of Ice & Water Shield
Not RequiredInspectorMike Lockman
Photos submitted and approved under a separate re-roof permit by another contractor. Permit GV121201
- Nov 13, 2024
Lath
CompletedInspectorMike Lockman
Lath on front bay addition. Proper installation w/ staples. Grade D paper installed behind lath as required
- Sep 25, 2024
Submit Pictures of House Wrap
CompletedInspectorBret Eggers
While on site for other inspections
- Sep 25, 2024
Framing
CompletedInspectorBret Eggers
Electrical inspection completed.
- Sep 25, 2024
Insulation
Completed in Future.InspectorBret Eggers
OK to final when Insulation report approved (attic)
- Sep 20, 2024
Foundation Insulation
CompletedInspectorMike Lockman
Foil backed rigid insulation installed on interior of crawlspace foundation walls. Seams to be covered w/ foil tape.
- Sep 20, 2024
Framing
Completed in Future.InspectorMike Lockman
All framing is SCWAP and may be approved once electrical RI inspection completed.
- Aug 26, 2024
Foundation Insulation
Partial ApprovalInspectorMike Lockman
1.5" Rigid foam insulation on exterior of foundation w/ 6 mil slip sheet. Contractor says they are applying another 1.5" insulation board on the interior of foundation. Verity in future.
- Aug 26, 2024
Foundation Waterproofing
CompletedInspectorMike Lockman
Spray applied waterproofing from top of footing to top of foundation wall
- Aug 20, 2024
Footing
CompletedInspectorMike Lockman
20x8 Strip footings w/ (2) #4 bar at bottom on suspended 2" above bottom of footing. Pinned into existing footings at intersecting locations w/ (2) #4 pins at each location.
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.