- Sep 17, 2025
Insulation
CompletedInspectorBret Eggers
Batts in all old walls spray in new addition
- May 15, 2025
Other
Permit ExtensionInspectorCandelaria Andrade-Deleg
Permit Extension approved for 3 months from 05/15/25 - 8/13/25
- Nov 21, 2024
Submit Pictures of House Wrap
CompletedInspectorBrian Stemwedel
Pictures emailed
- Nov 21, 2024
Submit Pictures of Ice & Water Shield
CompletedInspectorBrian Stemwedel
Pictures emailed
- Nov 14, 2024
Framing
CompletedInspectorBret Eggers
- Nov 1, 2024
Lath
CompletedInspectorMike Lockman
Lath on front elevation of home w/ 2 layers D grade paper. Wide crown staples for installation.
- Nov 1, 2024
Insulation
Partial ApprovalInspectorMike Lockman
Underfloor CC SPF insulation in the mud room/half bath area adjacent to the garage
- Aug 30, 2024
Foundation Waterproofing
CompletedInspectorBrian Stemwedel
liquid applied asphalt, projects over top of fnd.
- Aug 30, 2024
Foundation Insulation
CompletedInspectorBrian Stemwedel
draining type R-10
- Aug 30, 2024
Footing
CompletedInspectorBrian Stemwedel
ISCWAP
- Aug 30, 2024
Footing - Reinforcing
CompletedInspectorBrian Stemwedel
Dowels into existing footings
- Aug 27, 2024
Wall Reinforcing
CompletedInspectorMike Lockman
#4 bar vertical @ 5 ft OC
- Aug 27, 2024
Wall Reinforcing-Bond Beam
CompletedInspectorMike Lockman
#4 bar horizontal in bond beam. Lapped 20"+
- Aug 23, 2024
Footing
Partial ApprovalInspectorMike Lockman
14x20 strip footing for front stoop, 8x20 strip footings for addition on back of home and a 30x30x8 pad footing in crawlspace. SCWAP. Rear stoop footing not complete at time of inspection.
- Aug 23, 2024
Footing - Reinforcing
Partial ApprovalInspectorMike Lockman
#4 Bar suspended horizontally along bottom of strip footings. #4 Bar pinned into existing footing where footings intersect. SCWAP. Rear stoop footing not completed at time of inspection.