PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV120455

Building

2001 Regent Ave N, Golden Valley

IssuedAug 14, 2024
StatusUnknown
Value$800,000
Inspections15
Scope of work

Remodel/Alteration, Whole House Remodel and Addition

Location context
Parcel1802924230006
Coordinates44.99989, -93.34395
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$3,223.03
Total paid$3,223.03
Timeline
ApprovedAug 14, 2024
IssuedAug 14, 2024
Inspection record
Inspections15
Passed14
Failed0
  1. Sep 17, 2025

    Insulation

    Completed

    InspectorBret Eggers

    Batts in all old walls spray in new addition
  2. May 15, 2025

    Other

    Permit Extension

    InspectorCandelaria Andrade-Deleg

    Permit Extension approved for 3 months from 05/15/25 - 8/13/25
  3. Nov 21, 2024

    Submit Pictures of House Wrap

    Completed

    InspectorBrian Stemwedel

    Pictures emailed
  4. Nov 21, 2024

    Submit Pictures of Ice & Water Shield

    Completed

    InspectorBrian Stemwedel

    Pictures emailed
  5. Nov 14, 2024

    Framing

    Completed

    InspectorBret Eggers

  6. Nov 1, 2024

    Lath

    Completed

    InspectorMike Lockman

    Lath on front elevation of home w/ 2 layers D grade paper. Wide crown staples for installation.
  7. Nov 1, 2024

    Insulation

    Partial Approval

    InspectorMike Lockman

    Underfloor CC SPF insulation in the mud room/half bath area adjacent to the garage
  8. Aug 30, 2024

    Foundation Waterproofing

    Completed

    InspectorBrian Stemwedel

    liquid applied asphalt, projects over top of fnd.
  9. Aug 30, 2024

    Foundation Insulation

    Completed

    InspectorBrian Stemwedel

    draining type R-10
  10. Aug 30, 2024

    Footing

    Completed

    InspectorBrian Stemwedel

    ISCWAP
  11. Aug 30, 2024

    Footing - Reinforcing

    Completed

    InspectorBrian Stemwedel

    Dowels into existing footings
  12. Aug 27, 2024

    Wall Reinforcing

    Completed

    InspectorMike Lockman

    #4 bar vertical @ 5 ft OC
  13. Aug 27, 2024

    Wall Reinforcing-Bond Beam

    Completed

    InspectorMike Lockman

    #4 bar horizontal in bond beam. Lapped 20"+
  14. Aug 23, 2024

    Footing

    Partial Approval

    InspectorMike Lockman

    14x20 strip footing for front stoop, 8x20 strip footings for addition on back of home and a 30x30x8 pad footing in crawlspace. SCWAP. Rear stoop footing not complete at time of inspection.
  15. Aug 23, 2024

    Footing - Reinforcing

    Partial Approval

    InspectorMike Lockman

    #4 Bar suspended horizontally along bottom of strip footings. #4 Bar pinned into existing footing where footings intersect. SCWAP. Rear stoop footing not completed at time of inspection.