Permit / Golden Valley← Search
#GV123503

Building

1336 Lilac Dr N, Golden Valley

IssuedJan 13, 2025
StatusUnknown
Value$15,000
Inspections7
Scope of work

Remodel/Alteration, Reframing windows, master bed, Bed on 2nd floor & basement walls

Location context
Parcel1802924330080
Coordinates44.99224, -93.34907
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$71.34
Total paid$71.34
Timeline
ApprovedJan 13, 2025
IssuedJan 13, 2025
Inspection record
Inspections7
Passed5
Failed0
  1. Aug 22, 2025

    Final

    Completed

    InspectorMike Lockman

    Final approved. Correction completed
  2. Aug 14, 2025

    Other - Smoke & Carbon Alarm at Time of Final

    Completed

    InspectorMike Lockman

    Smoke and CO compliant
  3. Aug 14, 2025

    Framing

    Completed

    InspectorMike Lockman

    Corrections completed
  4. Aug 14, 2025

    Final

    Need Correction

    InspectorMike Lockman

    The 2 windows on either side of the porch door and the window at the landing on the staircase leading upstairs are not tempered. Contractor is allowed to install a protective film on these three windows. No other corrections found.
  5. Mar 20, 2025

    Insulation

    Completed

    InspectorMike Lockman

    FG batt insulation in UL and ML. CC spray foam in LL exterior walls and rim joists.
  6. Mar 20, 2025

    Framing

    Completed in Future.

    InspectorMike Lockman

    Noted corrections completed. Owner to also address the existing cut joist in the LL. Allowed him to email photo of repair
  7. Mar 13, 2025

    Framing

    Need Correction

    InspectorMike Lockman

    1. Sqash blocking required below J/K studs supporting header on ML adjacent to the staircase to carry load path to the foundation. 2. The holes bored in 2x6 floor joist for plumbing fail to meet the boring allowances of Section R502.8 3. A metal tie, compliant with Section R602.6.1, must be installed on the top plate where it is notched for the 3" plumbing stack installed adjacent to the stairs. Tie must be a minimum 1-1/2" wide and extend no less that 6" on either side of the opening. Correction letter emailed to permit holder

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.