PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV122665

Building

8505 Medicine Lake Rd, Golden Valley

IssuedMay 8, 2025
StatusUnknown
Value$40,000
Inspections8
Scope of work

New, Construct a Garage

Location context
Parcel3011821120022
Coordinates45.00734, -93.38795
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$727.03
Total paid$727.03
Timeline
ApprovedMay 6, 2025
IssuedMay 8, 2025
Inspection record
Inspections8
Passed7
Failed0
  1. Nov 3, 2025

    As-Built Survey

    Completed

    InspectorMike Lockman

    Received via email.
  2. Oct 30, 2025

    Framing

    Completed

    InspectorMike Lockman

    Framing completed. All corrections completed to be code compliant
  3. Oct 30, 2025

    Fire Stopping

    Completed

    InspectorMike Lockman

    Contractor provided photos showing 1/2" gyp installed on entire length of the overhang.
  4. Jul 14, 2025

    Submit Pictures of House Wrap

    Completed

    InspectorMike Lockman

    HW inspection completed while on site for framing inspection
  5. Jul 14, 2025

    Submit Pictures of Ice & Water Shield

    Completed

    InspectorMike Lockman

    IWS inspection completed while on site for the framing inspection
  6. Jul 14, 2025

    Framing

    Need Correction

    InspectorMike Lockman

    1. Missing anchor bolts on bottom plate at 5 locations around perimeter. 2. Portal framing required on front elevation at overhead doors. Required per Section R602 IRC. Contractor to reframe wall at overhead doors to be compliant or have an engineer provide a method to make the existing framing compliant. Including hold-downs 3. Contractor to install hold-down devices on the trusses as designed by the truss manufacturer. Truss documents to be on site at next inspection to verify installation compliance. 4. Electrical RI inspection must be completed prior to enclosing walls or closing permit Correction notice emailed to permit holder
  7. May 14, 2025

    Floor Slab

    Completed

    InspectorBrian Stemwedel

    2 34's cont. in turned down footing. slab reinforcement #4s 36" OC
  8. May 14, 2025

    Site - Verify Setbacks at Footing Inspection

    Completed

    InspectorBrian Stemwedel

    5'4" to property line in sw corner (closest spot. soffits will need to be 1 hr rated per R302 -or- solid blocking from top plate to roof decking between trusses