PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV126736

Building

380 Laurel Curve, Golden Valley

IssuedAug 6, 2025
StatusUnknown
Value$550,000
Inspections8
Scope of work

New, New Home

Location context
Parcel0511721210097
Coordinates44.97581, -93.37506
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$2,410.53
Total paid$2,410.53
Timeline
ApprovedAug 6, 2025
IssuedAug 6, 2025
Inspection record
Inspections8
Passed7
Failed0
  1. Oct 31, 2025

    Insulation

    Partial Approval

    InspectorMike Lockman

    Un-faced R20 FG batts w/ VP in exterior walls. Ceiling void above garage filled w/ cellulose. VB installed on UL ceiling. Attic insulation after drywall
  2. Oct 28, 2025

    Framing

    Completed

    InspectorBret Eggers

    A few minor correction made while inspection happened
  3. Oct 24, 2025

    Radon Control

    Completed

    InspectorMike Lockman

    Verified radon piping installed and terminated thru roof w/ R4 insulation. Passive system installed
  4. Sep 12, 2025

    Radon Control

    Partial Approval

    InspectorMike Lockman

    UG radon piping w/ 3" sch 40 pvc run above concrete. Perforated pvc installed 10 ft in 2 directions within the aggregate layer
  5. Sep 11, 2025

    Insulation - Under Slab

    Not Approved

    InspectorMike Lockman

    No insulation underslab. Just poly. Discoverd they did not have a radon control system installed. Contractor instructed not to place concrete until radon control is installed and ispected.
  6. Aug 14, 2025

    Foundation Insulation

    Completed

    InspectorMike Lockman

    R15 Rigid foam insulation installed on interior of foundation wall ( layer of 2" over layer of 1" )
  7. Aug 14, 2025

    Foundation Waterproofing

    Not Required

    InspectorMike Lockman

    Slab on grade home with balanced fill on entire foundation
  8. Aug 11, 2025

    Poured Wall

    Completed

    InspectorMike Lockman

    Reinforcement for poured wall foundation is substantially compliant w/ approved plans. #4 vertical bar @ 72" OC. #4 horizontal bar @ upper portion of wall. No water found in forms