PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV128317

Building

1045 Tyrol Tr, Golden Valley

IssuedOct 20, 2025
StatusUnknown
Value$250,000
Inspections8
Scope of work

Remodel/Alteration, First floor remodel includes new kitchen, mudroom/bathroom addition and dining room addition.

Location context
Parcel3002924140025
Coordinates44.97162, -93.33061
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$1,273.03
Total paid$1,273.03
Timeline
ApprovedOct 7, 2025
IssuedOct 20, 2025
Inspection record
Inspections8
Passed7
Failed0
  1. Feb 6, 2026

    Framing

    Completed

    InspectorGarrett Heins

    Point load carried to foundation with approved methods.
  2. Feb 6, 2026

    Insulation

    Completed

    InspectorGarrett Heins

    Closed cell spray foam used on all exterior walls, meeting or exceeding R value requirements. Fire blocking and draft stopping performed where required, fiberglass insulation installed in 2nd level floor joists for sound transmission.
  3. Jan 27, 2026

    Framing

    Need Correction

    InspectorGarrett Heins

    Point load blocking for steel beam opposite of sliding patio door required. Engineering and HVAC alteration possible. Contractor approved to continue project as long as continued load pathway remains visible in basement. All other framing is substantially compliant with approved plan and engineering provided.
  4. Jan 27, 2026

    Submit Pictures of House Wrap

    Partial Approval

    InspectorGarrett Heins

    House wrap and flashing of new windows on additions and anywhere siding was removed is approved.
  5. Nov 6, 2025

    Foundation Waterproofing

    Completed

    InspectorBret Eggers

  6. Nov 6, 2025

    Foundation Insulation

    Completed

    InspectorBret Eggers

    R10 foam board with slip sheet
  7. Nov 4, 2025

    Wall Reinforcing

    Completed

    InspectorMike Lockman

    Reinforcement for CMU wall at mud room addition. SCWAP
  8. Oct 31, 2025

    Footing

    Completed

    InspectorMike Lockman

    20 x 10 strip footing. SCWAP w/ 2 #4 H bar. Pinned into existing footing

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.