Permit / Golden Valley← Search
#GV128178Building
1850 Hampshire La, Golden Valley
IssuedNov 6, 2025
StatusUnknown
Value$70,000
Inspections13
Scope of work
Addition, 2 story addition
Location context
Parcel2911821420014
Coordinates44.99899, -93.36845
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$544.9
Total paid$544.9
Timeline
ApprovedOct 23, 2025
IssuedNov 6, 2025
Inspection record
Inspections13
Passed12
Failed0
- Mar 24, 2026
Final
CompletedInspectorMike Lockman
Final inspection approved. Smoke & CO alarms are compliant. Verified sticker for electrical final in panel dated 2/23/26. Exterior grading will be completed once the weather permits.
- Dec 23, 2025
Framing
CompletedInspectorGarrett Heins
4 Red head anchors added to southwest wall bottom plate.
- Dec 23, 2025
Insulation
CompletedInspectorGarrett Heins
Fiberglass insulation main level addition, R-49 roof, R-21 walls. Close cell spray foam for rim and basement addition against masonry. Vapor retarder with acoustical caulking over fiber glass insulation.
- Dec 19, 2025
Submit Pictures of House Wrap
CompletedInspectorGarrett Heins
Viewed at time of framing inspection.
- Dec 19, 2025
Submit Pictures of Ice & Water Shield
CompletedInspectorGarrett Heins
View photos at time of framing inspection. Ridge vent verified.
- Dec 19, 2025
Framing
Need CorrectionInspectorGarrett Heins
Anchor bolts required bottom plate on west wall. Approved engineered anchors allowed. SEE R403.1.6
- Nov 18, 2025
Drain Tile
CompletedInspectorMike Lockman
Exterior DT installed. Will terminated in a french drain in back yard
- Nov 18, 2025
Floor Slab-Reinforcement
CompletedInspectorMike Lockman
#4 FG bar reinforcement @ 24" OC EW
- Nov 13, 2025
Foundation Insulation
CompletedInspectorMike Lockman
ICF walls w/ 2" R10 in interior and exterior plain.
- Nov 13, 2025
Foundation Waterproofing
CompletedInspectorMike Lockman
Mel-Roll 60 mil self-adhering waterproofing membrane installed on exterior of ICF foundation
- Nov 13, 2025
Wall Reinf. inspect @ 4` lift prior to grout
CompletedInspectorMike Lockman
#5 Bar pinned @ 4 ft OC into strip footing and into existing foundation. #5 vertical bar @ 4 ft OC SCWAP. #4 FG bar horizontal @ 16 in OC for entire height of wall.
- Nov 12, 2025
Footing - Reinforcing
CompletedInspectorBret Eggers
As per approved plans
- Nov 12, 2025
Footing
CompletedInspectorBret Eggers
As per approved plans
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.