PULLFIRST[THE RECORD]
Permit / Golden Valley← Search
#GV129713

Plumbing

124 Paisley La, Golden Valley

IssuedJan 22, 2026
StatusUnknown
Value$12,000
Inspections2
Scope of work

Remodel/Alteration, Full bath remodel

Location context
Parcel3311821330041
Coordinates44.97971, -93.35851
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$338.72
Inspection record
Inspections2
Passed2
Failed0
  1. Mar 6, 2026

    Shower Pan ( if CT shower is being installed)

    Completed

    InspectorGarrett Heins

    Shower pan test performed for minimum of 3 hours, pitch verified.
  2. Jan 26, 2026

    Rough-In (Air Test-Plbg)

    Completed

    InspectorGarrett Heins

    R/I PVC for full bath with free standing tub and shower. Pex water lines run to mechanical room. Fernco's used for reconnection of upstairs bath and lav. Air test performed 5lbs for length of inspection.