Permit / White Bear Lake← Search
#WB090529Building
2517 Jansen Ave, White Bear Lake
IssuedOct 1, 2024
StatusUnknown
Value$301,158
Inspections14
Scope of work
New, NEW TOWNHOME (4 OF 4)
Location context
Fees & payments
Total fees$4,867.41
Timeline
ApprovedOct 1, 2024
IssuedOct 1, 2024
Inspection record
Inspections14
Passed12
Failed1
- Apr 2, 2026
Final Building Inspection
Partial FinalInspectorBEN EGGAN
Final approved pending: 1. Pour curb and restore boulevard landscaping 2. Provide Final Inspection Summary Report from Braun 3. Obtain rain garden approval from Connie Taillon 4. Install Handicap parking sign 5. Caulk all AC lines at exterior of the building 6. Repair and add flashing to fully cover foundation insulation
- Sep 30, 2025
Wall Bracing (Interior)
ApprovedInspectorBEN EGGAN
- Sep 19, 2025
Insulation
ApprovedInspectorBEN EGGAN
- Sep 4, 2025
Framing
FailedInspectorBEN EGGAN
Rough framing fialed. Correct the following: 1. Obtain fireplace permits and call for fireplace rogh in inspections. 2. Provide rated electrical box listing information. 3. Add lateral bracing and t-Bracing at roof trusses as required by the roof truss specifications. 4. Add drywall at drop soffit along the common fire wall. 5. Lower the leower level bedroom egress window to a maximum of 44" above the finished floor. 6. Add A35 clips at upper level top p[late per engineered design. 7. Provide your approved plan set on the job site. Correct and recall inspection
- Aug 5, 2025
Lath
ApprovedInspectorBEN EGGAN
- Jul 11, 2025
House Wrap (Email Pictures or On-Site Inspection)
ApprovedInspectorBEN EGGAN
- Jun 12, 2025
Floor Poly
ApprovedInspectorWILLY WEICHT
- Jun 9, 2025
Radon
Partial PassInspectorWILLY WEICHT
4" PVC pipe and 4" PVC pipe with sock in ground. Rock was already covering pipe and pictures were provided. None of above ground was completed at this inspection.
- Mar 11, 2025
Wall Bracing (Pre-Housewrap)
ApprovedInspectorWILLY WEICHT
- Dec 17, 2024
Rough Drain Tile
ApprovedInspectorWILLY WEICHT
- Dec 16, 2024
Foundation Pre-Backfill
ApprovedInspectorWILLY WEICHT
- Dec 16, 2024
Water Proofing
ApprovedInspectorWILLY WEICHT
- Dec 10, 2024
Foundation Pre-Pour
ApprovedInspectorWILLY WEICHT
- Nov 18, 2024
Footing
ApprovedInspectorWILLY WEICHT
Will send compaction report by Braun
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.