PULLFIRST[THE RECORD]
Permit / Crystal← Search
#CY088445

Building

6110 Lakeland Ave N, Crystal

IssuedNov 4, 2024
StatusUnknown
Value$494,564
Inspections17
Scope of work

New, New Residential Construction(Unit A) with ADU (Unit B)

Location context
Fees & payments
Total fees$10,162.03
Inspection record
Inspections17
Passed15
Failed2
  1. Dec 18, 2025

    Final - New Construction

    Partial approval

    InspectorJoe Tomasetti

    Need blower door test , will need $3000 for landscape escrow
  2. Sep 19, 2025

    Lathe

    Satisfactory as completed

    InspectorJoe Tomasetti

    Jumbo Tex with 60 min WRB ESR 1027 / ASTM E 2556
  3. Jul 31, 2025

    Firewall / Draft Stop

    Satisfactory as completed

    InspectorJoe Tomasetti

    2 layer type X gypsum
  4. Jul 31, 2025

    Siding - water-resistive barrier (house wrap)

    Satisfactory as completed

    InspectorJoe Tomasetti

  5. Jul 31, 2025

    Fdn Waterproofing

    Satisfactory as completed

    InspectorJoe Tomasetti

  6. Jul 31, 2025

    Roofing - Ice Barrier

    Satisfactory as completed

    InspectorJoe Tomasetti

  7. Jul 31, 2025

    Braced Wall

    Satisfactory as completed

    InspectorJoe Tomasetti

  8. Jun 6, 2025

    Insulation

    Satisfactory as completed

    InspectorJoe Tomasetti

    Unit A/B R 20 with 6 mil poly all seams taped or caulked
  9. Jun 4, 2025

    Framing - New Construction

    Satisfactory as completed

    InspectorJoe Tomasetti

  10. Apr 11, 2025

    Sub-Slab Preparation

    Satisfactory as completed

    InspectorJoe Tomasetti

    Both units A/B 6 mil poly 6 inch rock ,all seams lapped or taped
  11. Apr 10, 2025

    Firewall / Draft Stop

    Fails to comply

    InspectorJoe Tomasetti

  12. Apr 10, 2025

    Braced Wall

    Fails to comply

    InspectorJoe Tomasetti

  13. Apr 3, 2025

    Firewall / Draft Stop

    Partial approval

    InspectorJoe Tomasetti

    Add fire rated plywood to braced walls on garages Roof ok
  14. Nov 20, 2024

    Fdn Waterproofing

    Approved with corrections as noted

    InspectorJoe Tomasetti

    Block water proofed behind r 10 foam .foam has slip sheet on it ,remove foam on adu so concrete floor has solid contact with block. foam can installed on the outside of building .
  15. Nov 20, 2024

    Fdn Reinforcement

    Satisfactory as completed

    InspectorJoe Tomasetti

  16. Nov 7, 2024

    Masonry Reinforcement

    Partial approval

    InspectorJoe Tomasetti

    front of garage only ok
  17. Nov 6, 2024

    Footing

    Satisfactory as completed

    InspectorJoe Tomasetti

    10 X 20 inch footing with 2 # 4 rebar continuous,2 # 4 in jumps North side setback 11.46 south side setback 9.4

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.