Permit / Crystal← Search
#CY089612Building
7010 Dudley Ave N, Crystal
IssuedApr 7, 2025
StatusUnknown
Value$25,000
Inspections16
Scope of work
Alteration, Addition to back of house with new deck
Location context
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$683.33
Inspection record
Inspections16
Passed9
Failed7
- Jul 25, 2025
Final
Satisfactory as completedInspectorJoe Tomasetti
Per home owner ok to final
- Jul 21, 2025
Final
Fails to complyInspectorJoe Tomasetti
Use 2 X 2 X 10 not 2 X 2 X 8 Beam , add footing to center of beam call for inspection .
- Jul 15, 2025
Final
Fails to complyInspectorJoe Tomasetti
ADD 2 X 2 X 10 BEAM TO CENTER OF DECK OVER NEW FOOTINGS INSTALLED.
- Jul 9, 2025
Final
Fails to complyInspectorJoe Tomasetti
ADD 2 X 2 X 10 beam to center of deck over footings add center footing . Close stair risers
- Jun 26, 2025
Framing
Fails to complyInspectorJoe Tomasetti
Add beam to center of deck 2 X 10 will not span 16 feet. Add 2 X 2 X 10 to beam by house with center footing with 2 X 2 X 10 beam .
- Jun 10, 2025
Framing
Fails to complyInspectorJoe Tomasetti
Deck approved for 10 X 12 deck only .Stop all work until zoning approves deck
- May 20, 2025
Insulation
Satisfactory as completedInspectorJoe Tomasetti
R - 13 with 4 mil poly
- May 16, 2025
Insulation
Fails to complyInspectorJeni Taylor
Holes and gaps in paper backed insulation on walls.
- Apr 29, 2025
Insulation
Partial approvalInspectorJeni Taylor
R30 in floor
- Apr 29, 2025
Framing
Partial approvalInspectorJeni Taylor
2x4 studs 16 inch on center 2x10 floor joists 3 - 2x10 beams
- Apr 29, 2025
Roofing - Ice Barrier
Satisfactory as completedInspectorJeni Taylor
2 rows of ice and water barrier
- Apr 25, 2025
Framing
Partial approvalInspectorJoe Tomasetti
2 X 11 7/8 LVL Add mechanical fasteners to rafters on ridge beam.
- Apr 24, 2025
Framing
Partial approvalInspectorJoe Tomasetti
Per pictures and conversation with contractor ledger locks @ 8 inch o/c 2 x 10 joist 16 inch o/c
- Apr 24, 2025
Footing
Satisfactory as completedInspectorJoe Tomasetti
4 X 42 inch x 24 inch @ base for deck footings
- Apr 14, 2025
Footing
Satisfactory as completedInspectorJoe Tomasetti
8 inch x 23 wide at base 42 inch deep
- Apr 11, 2025
Footing
Fails to complyInspectorJoe Tomasetti
Plan shows 23 inch X 8 inch footing not 16 tube.
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.