PULLFIRST[THE RECORD]
Permit / Minnetonka← Search
#MI281471

Building

3061 Lake Shore Blvd, Minnetonka

IssuedJul 9, 2024
StatusUnknown
Value$1,120,650
Inspections20
Scope of work

New, New Construction

Location context
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedJul 9, 2024
IssuedJul 9, 2024
Inspection record
Inspections20
Passed16
Failed0
  1. Aug 8, 2025

    Residential Final

    APPROVED

    InspectorMarshall Lind

    Hand rails on interior OK, Fire blocking in mechanical room OK, Deck guard & hand rails OK
  2. Jul 15, 2025

    Residential Final

    CORRECTION NOTICE

    InspectorDan Menth

    Need continous full length handrails on stairs from main floor to 2nd and main floor to basement. Finish exterior decks, porch and railings
  3. Mar 4, 2025

    Foundation/Waterproofing

    APPROVED

    InspectorKevin McDermott

    All of this work has been done.
  4. Feb 27, 2025

    Residential Insulation

    APPROVED

    InspectorDan Menth

  5. Feb 24, 2025

    House Wrap/Lathing

    APPROVED

    InspectorMarshall Lind

    Lath on front of garage & 1 foot around each side OK
  6. Feb 13, 2025

    House Wrap/Lathing

    CANCELLED APPOINTMENT

    InspectorDan Menth

  7. Jan 8, 2025

    Residential Insulation

    PARTIAL APPROVAL

    InspectorDan Menth

    Seal penetrations thru draft stopping in floor trusses main and basement levels, need R-30 in sport court ceiling. Bedroom #6 egress window height ok
  8. Jan 2, 2025

    House Wrap/Lathing

    APPROVED

    InspectorDan Menth

    Extend wrap to bottom of top cord, West side soffit fire rated
  9. Jan 2, 2025

    Residential Framing

    APPROVED

    InspectorDan Menth

    Fire block dead space at energy walls, Bedroom #6 egress window 44" max to opening, will need R-30 in sport court ceiling
  10. Dec 23, 2024

    House Wrap/Lathing

    NOT READY

    InspectorKevin McDermott

    All penetrations need to be sealed up. Soffits within 5' of property lines need 5/8 gyp sheathing on bottom side. Call for reinspection.
  11. Nov 25, 2024

    House Wrap/Lathing

    CALL FOR REINSPECTION

    InspectorChris Weaver

    NOT COMPLETE QUESTIONED FIRE RATING ON EARLIER PLANS
  12. Sep 24, 2024

    SOG/Vapor Barrier

    APPROVED

    InspectorMarshall Lind

    Spancrete floor is waterproofed, R10 rigid insulation above spancrete and below garage floor OK, sports court below, will need a R30 insulation total
  13. Sep 23, 2024

    Radon

    APPROVED

    InspectorMarshall Lind

    House & sports court OK, Radon pipe to exterior inspected by KP 12/30/2024
  14. Sep 23, 2024

    SOG/Vapor Barrier

    APPROVED

    InspectorMarshall Lind

    House & sports court OK
  15. Sep 9, 2024

    Foundation/Waterproofing

    PARTIAL APPROVAL

    InspectorKevin McDermott

    Phase 2 -south side- waterproofing and R15. Discussed need for R30 separation from sport court to garage floor.
  16. Sep 5, 2024

    Poured Wall

    APPROVED

    InspectorDan Menth

    Remainder of South 1/2 projections ok, rebar per engineering
  17. Aug 29, 2024

    Residential Footing

    APPROVED

    InspectorDan Menth

    Remainder of footings, forms and rebar per engineering, sand/ gravel 86 deg
  18. Aug 16, 2024

    Foundation/Waterproofing

    PARTIAL APPROVAL

    InspectorKevin McDermott

    Lake side- Phase 1 -waterproofing OK. R10 on inside below grade, R15 on outside of foundation that will have living space. Exterior drain tile.
  19. Aug 13, 2024

    Poured Wall

    PARTIAL APPROVAL

    InspectorDan Menth

    North section projections ok, rebar per engineering
  20. Aug 9, 2024

    Residential Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Only doing North part of home, Footings & pads are North of stairs on plans, Marked with black line on plans in mailbox, Strip & pad footings per plan, No rebar in any of the footings, UFER rod tagged, Sand/gravel, 58 degrees, Dry

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.