Scope of work

Addition, 2 story Addition approx 37 x 40 includes a garage, living space, a dormer. Newwindows . siding and r

Location context
Parcel1411722330015
Coordinates44.93497, -93.43839
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedJul 15, 2024
IssuedJul 19, 2024
Inspection record
Inspections13
Passed10
Failed0
  1. Jul 22, 2025

    Residential Final

    APPROVED

    InspectorChris Weaver

    CORRECTIONS MADE ALL OK
  2. Jul 9, 2025

    Residential Final

    CORRECTION NOTICE

    InspectorChris Weaver

    ---MUST FINISH STAIRS AND HANDRAIL ---REAR DOORS MUST BE BLOCKED, >30" DROP ---SEAL UP ALL GARAGE DRYWALL
  3. Mar 11, 2025

    House Wrap/Lathing

    APPROVED

    InspectorMarshall Lind

    house wrap OK
  4. Mar 10, 2025

    Residential Framing

    APPROVED

    InspectorMarshall Lind

    Headers at overhang per engineer OK, Added engineering to project doc under As Built
  5. Mar 10, 2025

    House Wrap/Lathing

    CORRECTION NOTICE

    InspectorMarshall Lind

    Not ready, missing house wrap in places, Need to seal all penetrations, Need to seal ripped or cut house wrap, Call for re-inspection, Talked to homeowner on site stated he will call for re-inspection
  6. Feb 28, 2025

    Residential Framing

    SEE COMMENTS

    InspectorMarshall Lind

    Headers at rear living room window/Service door & hallway OK, CHANGED HEADER FOR FRONT OVER HANG FROM LVL'S TO 3 - 2 X 12'S NEED LETTER FROM ARCHITECT, Rest of front over hang framing OK, Talked to homeowner & contractor on site
  7. Jan 29, 2025

    Residential Insulation

    APPROVED

    InspectorKevin McDermott

    Corrections made. Insulation approved and attic card provided.
  8. Jan 27, 2025

    Residential Insulation

    PARTIAL APPROVAL

    InspectorKevin McDermott

    1st and 2nd floors. Ductwork in walls and garage ceiling don't allow for proper R20 and R30. Vapor barrier missing at mud room.
  9. Jan 21, 2025

    Residential Framing

    PARTIAL APPROVAL

    InspectorChris Weaver

    ---MISSING ALL WALL POINT LOADS AT GIRDER TRUSSES UP AND DOWN ---MISSING LATERALS ---PORTAL STRAPS TO BE TAKEN TO TOP PLATE
  10. Nov 14, 2024

    Residential Footing

    APPROVED

    InspectorKevin McDermott

    2 piers at front entry OK per plan.
  11. Sep 30, 2024

    Poured Wall

    PARTIAL APPROVAL

    InspectorChris Weaver

    ---WALL FORMS BARELY ON FOOTING ---VERTICAL REBAR RESTING ON FORM BECAUSE OF FOOTING MISPLACEMENT ADD ADDITIONAL FOOTING TO ACCOMODATE WALL POUR
  12. Sep 25, 2024

    Residential Footing

    APPROVED

    InspectorChris Weaver

    CENTER FOOTING NOW 3' WIDE, STEEL FOR UNDERPINNING ON SITE BUT NOT INSTALLED YET - REQUESTED PICTURES 70 DEG, CLAY
  13. Sep 10, 2024

    Residential Framing

    PARTIAL APPROVAL

    InspectorDan Menth

    East wall main and 2nd floor ok, South side shed roof ok