Inspection record
Inspections47
Passed38
Failed0
  1. Mar 11, 2025

    Foundation/Waterproofing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Grid 2 Grid K - D
  2. Mar 10, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    SOG / Vapor barrier Grid F - R Grid 13.5 - 17
  3. Mar 10, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Grid 2 Grid K - P.7
  4. Mar 5, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    North Elevator pit, Foundation grid P grid 3 - 4.4
  5. Mar 4, 2025

    Foundation Rebar/Form

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

    Canceled by Brad
  6. Mar 3, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip grid 1.9 grid Q-D, Strip grid 2 grid Q-D, Elevator pit grid N.3 - P grid 3 -4.4, Pads grid 2 grid M,K,H,E.9, D.8, D.3, Pad grid Q grid 3
  7. Feb 28, 2025

    Commercial Footing

    NOT READY

    InspectorMarshall Lind

    Nothing ready for today
  8. Feb 26, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    7 pads - Grid 12.2 P, Grid 12.2 P.7, Grid 12.7 P, Grid12.8 P.7, Grid 11.5 H5, Grid 11.5 G.3, Grid12.4 G.3
  9. Feb 25, 2025

    Foundation Rebar/Form

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

    Nothing ready for today
  10. Feb 24, 2025

    Commercial Final

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip Grid P - R Grid 1.9, Strip Grid R Grid 1.9 - 8, Strip grid 4.4 Grid Q - R, Pad grid N.3 grid 5, Pad grid Q grid 5, Pad grid N.3 grid 7
  11. Feb 21, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation & rebar Grid A 1-4, Grid A - C Grid 1
  12. Feb 19, 2025

    Commercial Footing

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

    Canceled per Brad due to cold weather 7:40
  13. Feb 14, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip footing Grid A 1 - 4, Strip footing Grid A - C Grid 1
  14. Feb 7, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation Grid 7.4 F - N, Grid N 7 - 8, Grid E7 7-8,5
  15. Feb 5, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation Grid N 8-10.3: Grid N-R 10.3:, Grid R 8-10.3
  16. Feb 5, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip Grid N-E.7 7.4: Grid E.7 7.4 - 8.5: 5 Pads Grid 5 M/L/J/G/E.3
  17. Feb 4, 2025

    Foundation Rebar/Form

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

  18. Feb 3, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip & pads Grid N 8-10,3, Grid N-R 10.3, Grid R 8-10.3, 4 Pads Grid E.3 Grid 7 & 5, Grid E Grid 8.5 & 9
  19. Jan 30, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorKevin McDermott

    Stoop footing fix on west side OK. Interior pad footings: 8.5/P,Q. 9/Q; 9.4/P.
  20. Jan 29, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Tall wall Grid Q-R Grid 13.5-14.6
  21. Jan 28, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Exterior foundation Grid 14-16 grid P-R, 2 Stoops Grid A Grid 12.9-14
  22. Jan 24, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation Grid 17 Grid F-P, Add chairs for rebar to be in correct location on forms
  23. Jan 22, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation wall Grid 12.2 Grid N-R Rebar OK
  24. Jan 22, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Pads Grid C Grid 15, Pad Grid C Grid 16 Rebar OK, Stoop footing Grid 13.5 Grid A.9 Have to epoxy rebar in waiting for Braun before installing
  25. Jan 17, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip footing Grid F-R Grid 17-13.5 Outside Radius Already poured, Pads Grid E 12.8 & Grid E12 already poured, Pad Grid E 11 rebar OK
Show 22 earlier inspections
  1. Jan 14, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Grid F Grid 9-14 Forms & rebar
  2. Jan 10, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Grid F-L.1 Grid 14.6, Grid F Grid 14-14.6, Grid E-L.1 Grid 13.5, Rebar installed no forms at this time
  3. Jan 7, 2025

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation Grid F 9-14
  4. Jan 3, 2025

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip & pad footings on Grid F , Grid 9-14.6, Pad on Grid D.4, Grid 15, Pads on Grid E, Grid 14.6 & 14 & 13.7
  5. Dec 27, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Grid E-F Grid 17.5 Need to add chairs, Grid F Grid 17.5-16.5 Add chairs, Walls WC2 & WC1
  6. Dec 20, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorKevin McDermott

    Wall forms: grid 21, 2.2- 13.7. RW1, CW7.
  7. Dec 19, 2024

    Commercial Footing

    CANCELLED APPOINTMENT

    InspectorKevin McDermott

    Cancelled due to inclement weather. Snow, 21 deg.
  8. Dec 17, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Strip footings Grid P.7-R, Grid 12.2-13.7
  9. Dec 16, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation Grid P-P7 Grid 13.5-14.6
  10. Dec 11, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorDale Gronberg

    POURED WALLS * Grids 16/D-L4: VERTS #7 OF, #5 IF @ #12" o.c. HORZ: #5 @ 18" o.c. * Grids 14A/B8: VERTS #4 @ 16" o.c. HORZ #4 @ 16" o.c.
  11. Dec 9, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    2 foundation walls, Grid 13.5 Grid A.9-B.3, Grid A.9 Grid 13.5-14.4
  12. Dec 6, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation wall Grid 9 A-B, Pier Grid 13.5 B.8
  13. Dec 4, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Elevator pit walls Grid 13-13.5 C-D, Pieir Grid 13 D
  14. Dec 3, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Piers grid D 4-12, CW2 Foundation walls Grid 4 A.6-B & B1-C
  15. Nov 27, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorDale Gronberg

    * Grids A & D/1-4 with WF8 & WF9 perimeter footings * Grid 4/A-D with WF9 and F-10 column pad
  16. Nov 26, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorChris Weaver

    S2.1B - 4-9/A STRIP FOOTING, STAIR TOWER FOOTING 4.5/A.5, A.5/4 TO 4/D STRIP WITH HUGE STEP AT 4/B.7 CONTINUING D.3/4 - D.3/9 STRIP FOOTING
  17. Nov 25, 2024

    Commercial Footing

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

    Canceled per EJ 9:00
  18. Nov 22, 2024

    Foundation Rebar/Form

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Foundation 13,5 - D OK
  19. Nov 19, 2024

    Commercial Footing

    CANCELLED APPOINTMENT

    InspectorMarshall Lind

    Per LJ at 8:30
  20. Nov 14, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorChris Weaver

    STRIP FOOTING 11-1.5/A, 11-12/B PAD 13/B, 12.1/B
  21. Nov 12, 2024

    Commercial Footing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Marked in green on plan, Strip & pads 13.5-14.6 A-D, 13.3-17 B.8-F
  22. Nov 8, 2024

    Commercial Footing

    NOT READY

    InspectorMarshall Lind

    Met with Brad & Doug on site, Canceled inspection, Not ready