#MI279665

Building

1584 Oakways, Minnetonka

IssuedSep 16, 2024
StatusUnknown
Value$100,000
Inspections12
Scope of work

Remodel/Alteration, interior house remodel and bumpout

Location context
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedFeb 22, 2024
IssuedSep 16, 2024
Inspection record
Inspections12
Passed5
Failed0
  1. Jun 3, 2025

    Residential Final

    APPROVED

    InspectorDan Menth

  2. May 13, 2025

    Required Carbon Monoxide Detector

    APPROVED

    InspectorMarshall Lind

    CO & SD in required locations OK
  3. May 13, 2025

    Residential Final

    CORRECTION NOTICE

    InspectorMarshall Lind

    Used after market film for tempering windows in upstairs bathroom, Needs approved product installed by certified installer & have correct labeling, Talked to contractor on site, Call for re-inspection NEED ELECTRICAL FINAL, MULTIPLE CORRECTION
  4. May 2, 2025

    Residential Final

    SEE COMMENTS

    InspectorMarshall Lind

    Does not appear the windows in master bathroom around soaking tub are safety glazed, talked to contractor on plumbing and mechanical fina, he didn't seem concerned
  5. Dec 9, 2024

    Residential Framing

    APPROVED

    InspectorMarshall Lind

    Framing OK
  6. Dec 5, 2024

    Meet Contractor

    SEE COMMENTS

    InspectorKevin McDermott

    Discussed stair width. Approved as built. No rail will be added on the wall, contractor to use the stair guard rail as the handrail.
  7. Oct 24, 2024

    Residential Framing

    CORRECTION NOTICE

    InspectorMarshall Lind

    Need to fix rim area that was cut out for mechanical, submit engineering, Emailed contractor 10/24/24 10:10 Call for re-inspection
  8. Oct 22, 2024

    Residential Insulation

    APPROVED

    InspectorMarshall Lind

    Poly has been sealed
  9. Oct 21, 2024

    Residential Insulation

    CORRECTION NOTICE

    InspectorMarshall Lind

    Need to seal along floor upstairs new insulation, All other batt insulation & poly OK, Talked to contractor on site
  10. Oct 16, 2024

    Residential Insulation

    NOT READY

    InspectorChris Weaver

  11. Oct 16, 2024

    Residential Framing

    PARTIAL APPROVAL

    InspectorChris Weaver

    --MISSING JACK SUPPORTS IN RESTROOM, PLUMBING IN THE WAY, WILL ADVISE ENGINEER ---STAIRS STILL ONLY 32", WILL COME UP WITH SOME REMEDY FRAMING OK
  12. Oct 14, 2024

    Residential Framing

    CORRECTION NOTICE

    InspectorChris Weaver

    MISSING REQUIRED KING AND JACK STUDS THROUGHOUT