Inspection record
Inspections15
Passed8
Failed0
- Jan 29, 2026
Residential Final
CORRECTION NOTICEInspectorBrian Stemwedel
Extruded polystyrene foundation insulation exposed @ foundation. Correction: Exterior non-draining foundation insulation shall be covered with approved weather-resistant protective covering installed over all exposed insulation to a point 6" below grade. [R402.1.1.3(5.) MN Res. Energy Code] Spoke with HO. will call once exterior insulation is covered
- Jan 7, 2026
Residential Framing
SEE COMMENTSInspectorBrian Stemwedel
Contractor submitted amended plans that show the wall added after the original plans were reviewed. this is in PDOX , file name: 5586 NANTUCKET REVISED BASEMENT PLANS
- Dec 16, 2025
Residential Framing
SEE COMMENTSInspectorBrian Stemwedel
Met with H.O., contractor, and electrical inspector (Keith O.). (2) walls not on plans, told contractor to revise plans and email to me so accurate records on as built conditions were recorded. Keith will require contractor to remove enough drywall to verify compliance with electrical code, also additional outlet required
- Nov 19, 2025
Residential Insulation
APPROVEDInspectorBrian Stemwedel
pictures provided of draftstopping at soffit(s) in basement
- Nov 13, 2025
Residential Insulation
APPROVEDInspectorBrian Stemwedel
corrections per M.L. verified
- Nov 12, 2025
Residential Framing
APPROVEDInspectorMarshall Lind
Framing for beam meets required fix from engineer, Floor joist meets allowable spans at spacing they are currently at. Framing OK
- Nov 12, 2025
Residential Insulation
CORRECTION NOTICEInspectorMarshall Lind
1. Poly on both floors needs to be sealed, Need fire blocking in main floor bathroom area, 3. Need to seal poly along top and around windows, 3. In rim area in basement need rim insulation, 4. Need poly & seal in dead space on main level, 5. Call for re-inspection, Talked to contractor & home owners on site
- Nov 12, 2025
House Wrap/Lathing
SEE COMMENTSInspectorMarshall Lind
Need to seal house wrap around sump basket discharge
- Oct 17, 2025
House Wrap/Lathing
APPROVEDInspectorDan Menth
Extend wrap to bottom of top cord, install drip caps
- Oct 17, 2025
Residential Framing
SEE COMMENTSInspectorDan Menth
Provide engineering on splices in LVL's and I joist span, plan shows 12" OC joists are at 19.2". provide 22"x30" attic access to new addition
- Oct 7, 2025
Meet Contractor
SEE COMMENTSInspectorMarshall Lind
Met with mechanical contractor about questions, during meeting, NOTICED IN BASEMENT FLOOR JOIST BEAM IS SPLICED AND THE SPLICE IS NOT ON TOP OF POST. CHECK ON FRAMING
- Jul 21, 2025
Vapor Barrier
APPROVEDInspectorMarshall Lind
Vapor barrier Only have sump pump for plumbing below grade
- Jul 21, 2025
Residential Footing
APPROVEDInspectorMarshall Lind
2 Pad footings OK
- Jul 18, 2025
Foundation/Waterproofing
APPROVEDInspectorDan Menth
Waterproofing ok, R-10 on exterior needs 6 Mil slip sheet, exterior drain tile with sock
- Jul 8, 2025
Residential Footing
PARTIAL APPROVALInspectorMarshall Lind
Exterior strip footings only OK Footings per plan, No special engineering, 82 degrees, Sand/clay, Dry, CALL FOR PAD FOOTINGS INSPECTION