#MI292904

Building

18719 Red Cherry Cir, Minnetonka

IssuedJul 21, 2025
StatusUnknown
Value$437,945
Inspections13
Scope of work

New, Build a new home

Location context
Parcel3111722310027
Coordinates44.89798, -93.51668
Loading map…
199 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedJul 17, 2025
IssuedJul 21, 2025
Inspection record
Inspections13
Passed7
Failed0
  1. Apr 8, 2026

    House Wrap/Lathing

    APPROVED

    InspectorDan Menth

    Lathe for stone ok
  2. Mar 20, 2026

    Residential Footing

    PARTIAL APPROVAL

    InspectorBrian Stemwedel

    looked at (1) pier footing per plans 48" deep with a 24" bell to support 5' x 5' 'deck' plans (Garage landing- stairs footings) also show another pier footing at base of stair, plans not sealed by engineer and no footing required at stair base if supported on garage slab, none the less, that footing was not dug or inspected
  3. Mar 5, 2026

    House Wrap/Lathing

    APPROVED

    InspectorChris Weaver

    PICS ON SITE
  4. Mar 4, 2026

    House Wrap/Lathing

    CORRECTION NOTICE

    InspectorMarshall Lind

    All penetrations must be sealed with flashing tape, No one on site, Phone number given does not go through. Call for re-inspection. Emailed contractor 3/4/26 9:40
  5. Feb 23, 2026

    Residential Framing

    APPROVED

    InspectorBrian Stemwedel

    Framing Corrections from 2/11 made
  6. Feb 23, 2026

    Residential Insulation

    PARTIAL APPROVAL

    InspectorBrian Stemwedel

    ***Does not include lids over Living area ML, Garage. told contractor to take pictures of attic markers and submit certificate at final. DC315 intumescent coating applied over SPF in crawlspace. Insulation approved: Garage walls- FG batt w/ VB ML walls- FG batt w/ VB Basement walls- SPF in rims, SPF over concrete foundation walls, FG batt w/ VB in framed walls
  7. Feb 11, 2026

    Residential Framing

    SEE COMMENTS

    InspectorBrian Stemwedel

    1. need to add fasteners (for uplift) at fron roof trusses over front window. 2. Missing (1) anchor bolt in garage w/ in 12" of splice. 3. SPF and Rigid foam installed in crawlspace needs to be protected per R316 -or- provide ES ER report demonstrating compliance w/ out prescriptive thermal/ ignition barrier. verify installation per evaluation report. ***Will take pictures of fasteners at front trusses (low side only) and anchor bolt in garage
  8. Jan 27, 2026

    Foundation/Waterproofing

    SEE COMMENTS

    InspectorBrian Stemwedel

    Rigid foam covering ground in crawlspace and SPF exposed on wall needs to be protected [R316.5.4 MRC]. Additionally, at the mechanical RI it was noted that the crawlspace did not have a supply. Crawlspaces need to be ventilated by one of the methods outlined in Section 408 MN Res. Code (usually a supply and passive return)
  9. Jan 27, 2026

    Residential Final

    SEE COMMENTS

    InspectorBrian Stemwedel

    Rigid foam covering ground in crawlspace and SPF exposed on wall needs to be protected [R316.5.4 MRC]. Additionally, at the mechanical RI it was noted that the crawlspace did not have a supply. Crawlspaces need to be ventilated by one of the methods outlined in Section 408 MN Res. Code (usually a supply and passive return)
  10. Nov 10, 2025

    Radon

    APPROVED

    InspectorBrian Stemwedel

    reviewed video of proper gas permeable layer covered w/ vb. Stopped by as well and verified VB was sealed as required
  11. Nov 5, 2025

    Radon

    CORRECTION NOTICE

    InspectorBrian Stemwedel

    missing Gas Permeable layer, contractor submitted alternate which needs to be reviewed prior to apptoval
  12. Sep 16, 2025

    Residential Footing

    APPROVED

    InspectorBrian Stemwedel

    contractor called and was able to fit in inspection for a 3'x3'x12" footing, in compliance with revised Eng. Note (emailed to C.W. on 9/12 at 9:15 am) also looked at a 15' section of strip footing at front corner of home w/ (2) #4's cont. doweled into ex. footings
  13. Aug 12, 2025

    Meet Contractor

    SEE COMMENTS

    InspectorDan Menth

    Met with contractor to review existing foundation after home was demo'd down to foundation, will need engineering on foundation, basement floor has many cracks and signs of settling, slab should be replaced