Inspection record
Inspections13
Passed12
Failed0
- Dec 16, 2025
Residential Insulation
APPROVEDInspectorDan Menth
- Dec 16, 2025
House Wrap/Lathing
APPROVEDInspectorDan Menth
- Dec 16, 2025
Residential Framing
APPROVEDInspectorMarshall Lind
Draft stopping in attic space in place after insulating OK
- Dec 8, 2025
Residential Framing
APPROVEDInspectorMarshall Lind
Correct headers installed, OK. Fire blocking in walls over 10 feet in height OK, STILL NEEDS DRAFT STOPPING IN ATTIC AFTER INSULATION HAS BEEN INSTALLED
- Dec 2, 2025
Residential Framing
CORRECTION NOTICEInspectorMarshall Lind
1. NEED 2 LVL'S FOR HEADER MAIN FLOOR BATHROOM, 2. NEED FIRE BLOCKING IN WALLS OVER 10 FEET IN HEIGHT STAIRS TO BASEMENT, 3. DRAFT STOPPING IN ATTIC HAS TO GO UP TO ROOF DECK left open at this time so they can insulate., Talked to contractors on site Trusses & bracing OK, All other headers/PSL's/Beams/Posts & mechanical fasteners OK, Hold downs & anchor bolts OK
- Nov 25, 2025
SOG/Vapor Barrier
APPROVEDInspectorDan Menth
Garage underslab vapor barrier ok
- Oct 28, 2025
SOG/Vapor Barrier
APPROVEDInspectorMarshall Lind
Poly under R10 rigid insulation, All penetrations sealed OK
- Oct 28, 2025
Radon
PARTIAL APPROVALInspectorMarshall Lind
Below slab, using interior drain tile into sealed basket OK, STILL NEED PIPE TO EXTERIOR
- Oct 20, 2025
Residential Framing
APPROVEDInspectorBrian Stemwedel
(3) gables 'bumped out' by 2x4 on edge (3 1/2") sheathed with 1/2" plywood and fastened in compliance with Table 602.3(3) MN Res. Code (6" edges and 12" field)
- Oct 7, 2025
Residential Framing
PARTIAL APPROVALInspectorMarshall Lind
BRACED WALLS & MAIN/LOWER LEVEL Sheathing OK, Still need to see gable ends
- Aug 12, 2025
Foundation/Waterproofing
APPROVEDInspectorDan Menth
Waterproofing ok, R10 needs slip sheet over rigid foam, exterior drain tile with rock and fabric
- Aug 4, 2025
Poured Wall
APPROVEDInspectorMarshall Lind
Foundation & rebar per engineering & plan OK, #4 & #5 18" vertical & horizontalm
- Jul 28, 2025
Residential Footing
APPROVEDInspectorChris Weaver
FOOTING AS PER PLAN, UFER PAINTED, SAND, 90 DEG, SUNNY FIREPLACE FOOTING NEED #5 EACH WAY @ 12",