PULLFIRST[THE RECORD]
Permit / Minnetonka← Search
#MI293119

Building

15100 Crestview La, Minnetonka

IssuedJul 22, 2025
StatusUnknown
Value$1,600,000
Inspections13
Scope of work

New, New construction of single family home

Location context
Parcel2811722130016
Coordinates44.91296, -93.47189
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedJul 22, 2025
IssuedJul 22, 2025
Inspection record
Inspections13
Passed12
Failed0
  1. Dec 16, 2025

    Residential Insulation

    APPROVED

    InspectorDan Menth

  2. Dec 16, 2025

    House Wrap/Lathing

    APPROVED

    InspectorDan Menth

  3. Dec 16, 2025

    Residential Framing

    APPROVED

    InspectorMarshall Lind

    Draft stopping in attic space in place after insulating OK
  4. Dec 8, 2025

    Residential Framing

    APPROVED

    InspectorMarshall Lind

    Correct headers installed, OK. Fire blocking in walls over 10 feet in height OK, STILL NEEDS DRAFT STOPPING IN ATTIC AFTER INSULATION HAS BEEN INSTALLED
  5. Dec 2, 2025

    Residential Framing

    CORRECTION NOTICE

    InspectorMarshall Lind

    1. NEED 2 LVL'S FOR HEADER MAIN FLOOR BATHROOM, 2. NEED FIRE BLOCKING IN WALLS OVER 10 FEET IN HEIGHT STAIRS TO BASEMENT, 3. DRAFT STOPPING IN ATTIC HAS TO GO UP TO ROOF DECK left open at this time so they can insulate., Talked to contractors on site Trusses & bracing OK, All other headers/PSL's/Beams/Posts & mechanical fasteners OK, Hold downs & anchor bolts OK
  6. Nov 25, 2025

    SOG/Vapor Barrier

    APPROVED

    InspectorDan Menth

    Garage underslab vapor barrier ok
  7. Oct 28, 2025

    SOG/Vapor Barrier

    APPROVED

    InspectorMarshall Lind

    Poly under R10 rigid insulation, All penetrations sealed OK
  8. Oct 28, 2025

    Radon

    PARTIAL APPROVAL

    InspectorMarshall Lind

    Below slab, using interior drain tile into sealed basket OK, STILL NEED PIPE TO EXTERIOR
  9. Oct 20, 2025

    Residential Framing

    APPROVED

    InspectorBrian Stemwedel

    (3) gables 'bumped out' by 2x4 on edge (3 1/2") sheathed with 1/2" plywood and fastened in compliance with Table 602.3(3) MN Res. Code (6" edges and 12" field)
  10. Oct 7, 2025

    Residential Framing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    BRACED WALLS & MAIN/LOWER LEVEL Sheathing OK, Still need to see gable ends
  11. Aug 12, 2025

    Foundation/Waterproofing

    APPROVED

    InspectorDan Menth

    Waterproofing ok, R10 needs slip sheet over rigid foam, exterior drain tile with rock and fabric
  12. Aug 4, 2025

    Poured Wall

    APPROVED

    InspectorMarshall Lind

    Foundation & rebar per engineering & plan OK, #4 & #5 18" vertical & horizontalm
  13. Jul 28, 2025

    Residential Footing

    APPROVED

    InspectorChris Weaver

    FOOTING AS PER PLAN, UFER PAINTED, SAND, 90 DEG, SUNNY FIREPLACE FOOTING NEED #5 EACH WAY @ 12",

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.