Permit / Minnetonka← Search
#MI294523Building
13145 Ridgedale Dr, Minnetonka
IssuedAug 8, 2025
StatusUnknown
Value$814,464
Inspections5
Scope of work
Remodel/Alteration, Interior remodel of an Existing Mercantile int. space; no ext. scope or occupancy change.
Location context
Parcel0311722420022
Coordinates44.96986, -93.44513
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedAug 8, 2025
IssuedAug 8, 2025
Inspection record
Inspections5
Passed2
Failed0
- Nov 20, 2025
Commercial Final
APPROVEDInspectorBrian Stemwedel
emergency lighting, exit signs, and all other issues identified at inspections addressed. life safety compliant- OK to Open occupy
- Nov 20, 2025
Commercial Insulation
INSPECTION NOT REQUIREDInspectorBrian Stemwedel
no exterior walls touched
- Nov 4, 2025
Commercial Final
NOT READYInspectorBrian Stemwedel
store wanted partial occupancy of area(s) outside of construction barriers. told contractor that exits would require signage (missing exit signs for rear exit) signs need to direct people from occupied area(s) to exits. so (3) needed for back exit and (1) for front at this point. will re assess at final but after speaking to Dale, with the plans showing 11 exits, some in center of store can be eliminated. also noted single wall vent connector for WH had a back pitch and was not supported (at all). verify vent supported and has proper pitch
- Oct 27, 2025
Commercial Final
NOT READYInspectorBrian Stemwedel
they were looking to occupy partial area of sales floor. M occupancy with >50 occupants (Over 5800 sq. ft. ) needs 2nd exit. cannot exit through storage room/ construction area. do not have compliant egress
- Oct 16, 2025
Commercial Framing
APPROVEDInspectorBrian Stemwedel
Steel framing to grid (6" above grid termination) Plenum ceiling. Contractor was moving water heater (gas) told him B Vent could not run through plenum (back room)
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.