#MI294336

Building

921 Carlson Pkwy, Minnetonka

IssuedSep 12, 2025
StatusUnknown
Value$1,156,915
Inspections8
Scope of work

New, 4-unit, 3 story, wood framed condo building

Location context
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedSep 12, 2025
IssuedSep 12, 2025
Inspection record
Inspections8
Passed5
Failed0
  1. Jan 20, 2026

    Commercial Framing

    PARTIAL APPROVAL

    InspectorMarshall Lind

    BRACED WALL INSPECTION ONLY OK
  2. Jan 16, 2026

    Commercial Framing

    CORRECTION NOTICE

    InspectorMarshall Lind

    BRACED WALL INSPECTION, Need to meet required nailing schedule, 4" edges & 8" Field, Call for re-inspection, Talked to contractor on site
  3. Dec 29, 2025

    Commercial Framing

    SEE COMMENTS

    InspectorBrian Stemwedel

    Check separation distance between 917 and 921 and make sure it is a min (or exactly 10' apart) if exterior walls are closer than 10', then per Table 602 MSBC 1 hour fire resistance rating is required from both sides [705.5 MSBC] distance is measured to lot line between buildings. if less than 5' from property line, then openings are also limited to 15% of exterior wall area
  4. Nov 5, 2025

    Commercial Framing

    PARTIAL APPROVAL

    InspectorBrian Stemwedel

    looking at firestop system, noted 3" pvc installed w/out fire collars. Verify via approved firestop details this is acceptable. Additionally, at 3" pvc, annular space was not symmetrical, if elimination of Fire collar is acceptable verify annular space requirements are in compliance
  5. Oct 22, 2025

    Poured Wall

    APPROVED

    InspectorBrian Stemwedel

    Fnd waterproofing approved (emulsified asphalt) told Randy that i would accept pictures of R10 rigid foam fnd insulation
  6. Oct 17, 2025

    Poured Wall

    APPROVED

    InspectorMarshall Lind

    Rebar per plan OK
  7. Oct 15, 2025

    Poured Wall

    NOT READY

    InspectorMarshall Lind

    Poured wall forms & rebar not ready, Call for re-inspection, Talked to GC & concrete forman
  8. Oct 13, 2025

    Commercial Footing

    APPROVED

    InspectorMarshall Lind

    Strip, Rebar per Structural, UFER rods tagged, Clay/Sand, Dry, 55 Degrees