Permit / Minnetonka← Search
#MI296198Building
15330 Knob Hill Cur, Minnetonka
IssuedSep 25, 2025
StatusUnknown
Value$20,000
Inspections9
Scope of work
Remodel/Alteration, front stoop modification, window replacement, updating staircase
Location context
Parcel2811722340047
Coordinates44.90883, -93.47457
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$20
Total paid$20
Timeline
ApprovedSep 25, 2025
IssuedSep 25, 2025
Inspection record
Inspections9
Passed7
Failed0
- Dec 12, 2025
Required Carbon Monoxide Detector
APPROVEDInspectorMarshall Lind
CO & SD in required area OK
- Dec 12, 2025
Residential Final
APPROVEDInspectorMarshall Lind
Electrical inspection passed, All else OK, All corrections OK
- Dec 8, 2025
Required Carbon Monoxide Detector
CORRECTION NOTICEInspectorMarshall Lind
Need CO detector downstairs within 10 feet of bedroom doors, Talked to contractor on site
- Dec 8, 2025
Residential Final
CORRECTION NOTICEInspectorMarshall Lind
Need CO Need electrical final Talked to contractor on site Rest of remodeling OK
- Nov 5, 2025
Residential Framing
APPROVEDInspectorBrian Stemwedel
reviewed pictures of framing angles
- Oct 27, 2025
Residential Framing
APPROVEDInspectorBrian Stemwedel
Remaining framing over front stoop. rafter ends carried by (3) ply 2x8. contractor asked to eliminate joist hangers on ceiling over stoop to facilitate application of tongue and groove. told him to add framing angles to one side of each ceiling joist and take pictures. (minor load of tongue and groove ceiling only)
- Oct 3, 2025
Residential Footing
APPROVEDInspectorBrian Stemwedel
Verified CMU footing (existing) for original stoop was supported on frost footings. allowed him to not place th (3) pier footings adjacent that strip footing. he also stated he would place #4's on a 12" O.C. grid, tied to verts j hooked into bottom of remaining (3) pier footings (with a 20+" bell)
- Sep 30, 2025
Residential Insulation
APPROVEDInspectorBrian Stemwedel
Closed cell SPF in in fill @ exterior wall (stairs) Also basement exterior walls Draftstopping required at wall/ soffit in basement. Told contractor would accept pictures of draftstops
- Sep 30, 2025
Residential Framing
PARTIAL APPROVALInspectorBrian Stemwedel
Interior framing (does not include porch) stairs re built to increase compliance of rise and run (better than it was) existing landing has just under 36" in direction of travel but >36" at walkline Window was not installed yet but will need to be SG
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.