PULLFIRST[THE RECORD]
Permit / Duluth← Search
#CSHVACR-2510-0799

HVAC (New or Full System Replacement) - 1 or 2 Family Dwelling

116 Katherine Ln, Duluth

IssuedOct 28, 2025
StatusIssued
Value$45,000
InspectionsNone listed
Scope of work

**ASAP permit please if possible** Installation of radiant in floor loops, ran in 1/2in pex with a 3/4in header Flow control manifolds on loops Weil McLain Ecotec 110 boiler, located in mechanical room per plans Taco 4 zone control Zoned with pumps, grund 15-58 - ZONED WITH MANIFOLD UPDATED 3/16 Mitsubishi 2 head mini split, one head living room, one master bedroom. MXZ3D24NL outdoor condenser MSZGX18NL 18K head MSZGX06NL 06K head Outdoor condenser to be located front of house between entryway and deck Air exchanger, located in mechanical room Air exchanger model: FFLEX100H 2 push button timers and one main humidistat Bathroom fan to be installed and vented to exterior in hard pipe with hood on exterior Bathroom fan model: PANFV0511VQL1 AIR EXCHANGER FOR APARTMENT ABOVE GARAGE. ADD A MINISPLIT UPSTAIRS

Location context
Inspection record

No inspections recorded.

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.