PULLFIRST[THE RECORD]
Permit / Edina← Search
#ED217305

Building

5501 Dewey Hill Rd 223, Edina

IssuedNov 19, 2024
StatusUnknown
Value$192,000
Inspections6
Scope of work

Alteration/Remodel, Remodel Condo Unit #223

Location context
Parcel0811621420295
Coordinates44.86914, -93.36349
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$960
Total paid$960
Timeline
ApprovedNov 14, 2024
IssuedNov 19, 2024
Inspection record
Inspections6
Passed4
Failed0
  1. Jul 28, 2025

    Building Final - COMMERCIAL

    Partial Approval

    InspectorTedd Nelson

    - Provide the listed and tested documents for the wafer lights
  2. Jul 14, 2025

    Final (includes smoke and CO alarms)

    Not Approved

    InspectorBrian Crask

    -Need Plumbing & MECH Final inspections -Need Gypsum/FR Construction inspection completed. -Insulation inspection missed.
  3. Feb 13, 2025

    Bldg Progress

    Progress Report

    InspectorTedd Nelson

    - Fire stopping for the fire place flue is compete top and bottom - Repair and patching is complete in the 2hr wall
  4. Feb 12, 2025

    Bldg Progress

    Progress Report

    InspectorTedd Nelson

    - Left a message with Cory the electrical contractor on protecting the membrane penetration. his #763-286-7058
  5. Feb 11, 2025

    Gypsum/FR Construction

    Not Approved

    InspectorTedd Nelson

    - Fire stop at the fire place flue penetration through the ceiling. - Repair and patch the penetrations in the 2hr wall with the correct lap - Provide a listed and tested light or cover for all the light penetrations in the ceiling
  6. Feb 4, 2025

    Framing-Commercial

    Approved

    InspectorPeter Akmenkalns

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.