Scope of work

Alteration/Remodel, Garage Heater Install Including Gas Line

Location context
Parcel2002824330104
Coordinates44.89211, -93.32584
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$102.14
Inspection record
Inspections4
Passed4
Failed0
  1. Feb 20, 2025

    Gas Line Air Test

    Approved

    InspectorJim G Meyer

    held air and label line
  2. Feb 19, 2025

    Rough-In

    Approved

    InspectorJim G Meyer

    all work was fixed per correction notes and saw final pics from owner approved work
  3. Jan 21, 2025

    Rough-In

    Not Approved

    InspectorJim G Meyer

    no 2 psi labeling no fire caulk on pipe through wall valves installed are appliance valves on gas line dirt leg tee installed is incorrect see gas piping picture in MMC 2020 no electric permit pulled wiring incorrect gave contractor a call left message to fix problems by friday the 24 of jan also told homeowner about all problems and what i was goint to have them do and by when
  4. Jan 17, 2025

    Final

    Not Approved

    InspectorJim G Meyer

    items to be fixed -incorrect dirt leg tee installed at unit see MMC 2020 gas piping -incorrect install of the csst piping black shielding needs to be done to specs for product sleeve needs to be in fitting -need to remove and install a full port valve on the gas line not a appliance shut off in side and at unit -also label gas line per code 2 psi -fire caulk opening where pipe goes through -need a permit for electrical wiring per city