Building
5115 Lake Ridge Rd, Edina
New, New Home with deck
- Dec 9, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Nov 26, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
Fall Inspection Site is OK (Inspected by Drew Hollister)
- Nov 21, 2025
Erosion Ctrl/Const Entrance
Not ApprovedInspectorLindsay Evans
Fall Inspection Clear Biffy and materials out of city ROW (Inspected by Drew Hollister)
- Nov 13, 2025
Lath
ApprovedInspectorScot Jandro
- Nov 4, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Oct 15, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Oct 2, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Sep 26, 2025
Lath
Partial ApprovalInspectorBrian Crask
Lath for 2 chimneys is approved.
- Sep 18, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Sep 8, 2025
Insulation
ApprovedInspectorGodwin Annin
- Sep 5, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Sep 2, 2025
Framing-New Home
ApprovedInspectorPeter Akmenkalns
adding more anchor blots in basement plates not enough left where concrete buys placed them
- Aug 20, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Aug 20, 2025
Bldg Progress
Not ApprovedInspectorPeter Akmenkalns
Fire places have issues see comment below need to be corrected BEFORE framing inspection check then: main level approved basement not approved. vent goes though floor system and is pitched down for about 6' and mech flex ducts are in contact with pipe. Min 3'' On top and 1'' on sides and bottom to combustible required.
- Aug 4, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Jul 24, 2025
Floor Slab
ApprovedInspectorScot Jandro
- Jul 23, 2025
Framing-New Home
Not ApprovedInspectorBrian Crask
This was a partial framing inspection, limited to the point loads at the exterior walls. -Missing squash blocks in 4 locations.
- Jul 11, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Jul 9, 2025
Erosion Ctrl/Const Entrance
Progress ReportInspectorLindsay Evans
Clean up street around entrance area
- Jun 20, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- Jun 20, 2025
Construction Fence
ApprovedInspectorLindsay Evans
- Jun 6, 2025
Erosion Ctrl/Const Entrance
Approved, w/ CommentsInspectorLindsay Evans
Contractor got back to me and said they were doing that to not damage the street due to the equipment they were driving on/off the site
- Jun 5, 2025
Construction Fence
Progress ReportInspectorLindsay Evans
Partial fence up. Need to install around remaining area to fully enclose excavated area with steep slopes
- Jun 5, 2025
Erosion Ctrl/Const Entrance
Progress ReportInspectorLindsay Evans
Lots of sand in street (looks intentional so reached out to contractor as to why)
- Jun 2, 2025
Foundation Pre-Backfil
Partial ApprovalInspectorBrian Crask
-Foundation insulation,waterproofing & drain tile approved. -Need to submit as-built TOF survey for review.
Show 8 earlier inspections
- May 30, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorAndy Reinisch
Spring 2025 Seasonal * Site looked good
- May 23, 2025
Poured Foundation Reinforcement
ApprovedInspectorGodwin Annin
- May 13, 2025
Footing
ApprovedInspectorPeter Akmenkalns
- May 13, 2025
Shoring needs to be done before footing inspection
ApprovedInspectorPeter Akmenkalns
far enough from lot lines not required.
- May 12, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans
- May 12, 2025
Construction Fence
ApprovedInspectorLindsay Evans
- May 5, 2025
Residential Redevelopment Coordinator
No Physical Inspection DoneInspectorLindsay Evans
Contractor emailed the well sealing record H406542. I saved to PDox and also forwarded to Engineering.
- Apr 29, 2025
Erosion Ctrl/Const Entrance
ApprovedInspectorLindsay Evans