PULLFIRST[THE RECORD]
Permit / Edina← Search
#ED222011

Building

7200 France Ave S, Edina

IssuedJul 2, 2025
StatusUnknown
Value$8,721,809
Inspections40
Scope of work

New, Footing and Foundation

Location context
Parcel3102824140001
Coordinates44.87268, -93.32911
Loading map…
199 nearby
This permitNearby
Fees & payments
Total fees$205
Total paid$205
Timeline
ApprovedJun 30, 2025
IssuedJul 2, 2025
Inspection record
Inspections40
Passed38
Failed0
  1. Mar 24, 2026

    Floor Slab

    Partial Approval

    InspectorTedd Nelson

    - Unit deck pour extension. level 1 east and north side
  2. Mar 24, 2026

    CMU Fdn Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - CMU grout at level 1 west perimeter wall
  3. Mar 24, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorTedd Nelson

  4. Mar 12, 2026

    CMU Fdn Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - CMU grouting level -1 level at Grids; 3 to 5
  5. Mar 12, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorTedd Nelson

  6. Mar 12, 2026

    Floor Slab

    Partial Approval

    InspectorTedd Nelson

    - Unit deck pour extension. level 2. 5 pours on east side
  7. Mar 10, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorPeter Akmenkalns

  8. Mar 10, 2026

    CMU Fdn Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    level 2 misc concrete infills to plane out for framing
  9. Mar 3, 2026

    Floor Slab

    Partial Approval

    InspectorPeter Akmenkalns

    ramp to p2 D-G 1-3
  10. Mar 3, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorPeter Akmenkalns

  11. Feb 24, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorPeter Akmenkalns

  12. Feb 24, 2026

    Floor Slab

    Partial Approval

    InspectorTedd Nelson

    - Vapor barrier for slab on grade, -2 level at Grids: 3 to 5 and G to M
  13. Feb 17, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorPeter Akmenkalns

  14. Feb 17, 2026

    Floor Slab

    Partial Approval

    InspectorPeter Akmenkalns

    P2 level slab on grade and vapor barrier 1-5 A-G
  15. Feb 10, 2026·1:00 PM - 2:00 PM

    Poured Foundation Reinforcement

    scheduled

    InspectorTedd Nelson

  16. Feb 10, 2026

    Floor Slab

    Partial Approval

    InspectorTedd Nelson

    - Vapor barrier for slab on grade, -2 level at Grids: 5 to7 and A to M
  17. Feb 6, 2026

    Floor Slab

    Partial Approval

    InspectorPeter Akmenkalns

    7.5 A-H P2 level slab on grade
  18. Feb 6, 2026

    Erosion Ctrl/Const Entrance

    Partial Approval

    InspectorPeter Akmenkalns

  19. Jan 7, 2026

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    last of exterior foundation below grade G-J on 1
  20. Oct 30, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    wall foundation section L-K 1
  21. Oct 24, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - 3rd level foundation wall at Grid: K; 1 to 4...38'
  22. Oct 22, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - Lower level foundation wall at Grid: K; 1 to 4
  23. Oct 17, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    FOUNDATION WALL 1 C-G
  24. Oct 14, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    - lower level foundation 9-5 M
  25. Oct 9, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - Lower level foundation wall at Grid: 10; K to M and M; 10 to 7.5
Show 15 earlier inspections
  1. Oct 6, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - Lower level foundation wall at Grid: 10; F to K
  2. Oct 1, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - Lower level foundation wall at Grid: 10; B to F
  3. Sep 26, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorTedd Nelson

    - Lower level foundation wall at Grid: A; 6.5 to 10
  4. Sep 23, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    foundation wall section along A 4-7
  5. Sep 19, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    -N W corrner 2 wall sections - 1 A- C - A 1-4
  6. Sep 17, 2025

    Footing

    Cancelled

    InspectorPeter Akmenkalns

  7. Sep 16, 2025

    Footing

    Partial Approval

    InspectorTedd Nelson

    - Pads at Grids: H6, H5, H4, H3, H2, J6, J5, J4, J3, J2 - Cont. at Grid: 1; L to G
  8. Sep 12, 2025

    Footing

    Partial Approval

    InspectorTedd Nelson

    - Continuous at Grids: M; 9-1 - Pads at Grids: L8, L7, L6. K.8-4, K.8-2 and Stairs L-L.8 to 5-5.25
  9. Sep 9, 2025

    Footing

    Partial Approval

    InspectorTedd Nelson

    - Continuous at Grid: 1; B to G and 3; B.5 to G - Pads at Grids: 4E, 4F, 4G, and E; 5 to 6
  10. Sep 8, 2025

    Footing

    Partial Approval

    InspectorTedd Nelson

    - Pads at Grids: 7E, 7F, 7G, 6F, 6G, 5F, 5G
  11. Sep 5, 2025

    Footing

    Partial Approval

    InspectorPeter Akmenkalns

    - (3)pad E-G on grid 8
  12. Sep 5, 2025

    Poured Foundation Reinforcement

    Partial Approval

    InspectorPeter Akmenkalns

    -elevator pit walls
  13. Sep 4, 2025

    Footing

    Partial Approval

    InspectorPeter Akmenkalns

    - strip perimeter footing A-M - pads 10 total D 1-9 and 2 on 9D 9E
  14. Sep 3, 2025

    Footing

    Partial Approval

    InspectorPeter Akmenkalns

    -elevator pit footings area H-K 8-7 and 1 Pad all poured as 1 with elevatorpit - 5 pads along L-F on 9
  15. Aug 29, 2025

    Footing

    Partial Approval

    InspectorTedd Nelson

    - Continuous with pads at Grid: A; 1 to 10 - Pads, Grids: B; 1 to 10 - Continuous, Grids: 1; A-B.5 and 10; A-B.5