Permit / Edina← Search
#ED220545Building
5801 Fairfax Ave, Edina
IssuedDec 9, 2025
StatusUnknown
Value$150,000
Inspections14
Scope of work
Addition, Tear down current structure down to foundation.MUST LEAVE MIN 50% OF OLD EXTERIOR WALLS
Location context
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$750
Total paid$750
Timeline
ApprovedDec 2, 2025
IssuedDec 9, 2025
Inspection record
Inspections14
Passed13
Failed0
- Apr 9, 2026
Insulation
Not ApprovedInspectorBrian Crask
-House-wrap requires full approval before insulation inspection can be fully approved. Contractor has been notified and is planning to call for WRB inspection. Insulation is approved pending house-wrap inspection.
- Apr 9, 2026
Framing
Partial ApprovalInspectorBrian Crask
Outstanding Items need for full framing approval: Deck framing & footings are TBD and to be inspected at a later date. Approval: House framing is now approved Note: photo submitted of one remaining item clearly showing compliance. -Deck is TBD and to be inspected at a later date.
- Apr 7, 2026
Framing
Not ApprovedInspectorBrian Crask
-Missing stringer header bearing. -Deck TBD at a later date
- Apr 6, 2026
Insulation
Partial ApprovalInspectorGodwin Annin
- Contractor to reschedule for framing inspection before sheet rocking the entire house.
- Apr 2, 2026
Framing
Partial ApprovalInspectorBrian Crask
-Missing center bearing wall headers in basement -Need full bearing to foundation at gaps under bottom plate at basement center bearing wall. -Contractor planning to add L bracket to stringer header for bearing. -Dec TBD at a later date. Notre: Okay to insulate.
- Mar 31, 2026
Framing
Not ApprovedInspectorBrian Crask
-Missing LVL rim board. Contractor planning to get revised plans for all related engineering. -Missing stringer attachment to stringer header, not per engineered design. -Missing 3ply studs at stairwell -Missing rim board at stair well -Missing center bearing wall headers in basement -Contractor planing to add L-Bracket rated for use as a joist hanger at connection to LVL beam in basement. -Missing one bottom plate anchor bolt in garage -Deck TBD at a later date
- Mar 9, 2026
Footing
ApprovedInspectorBrian Crask
Pad footing now approved Note: All footings are now approved.
- Mar 9, 2026
Framing
Partial ApprovalInspectorBrian Crask
Partial inspection on roof trusses only. Roof trusses are approved.
- Mar 9, 2026
Weather Barrier/Flashing
Progress ReportInspectorBrian Crask
95% of the WRB is installed and per code. Contractor states that siding crew is planning to install drip caps for windows and patch in remaining WRB per their typical process.
- Feb 27, 2026
Footing
Not ApprovedInspectorBrian Crask
-Pad footing form size & location is per engineering by MN P.E.. Thomas A. Webber Dated 12/17/2025. Contractor found an existing 4" drain line running through the new pad footing location. Contractor is planning to remove the pipe running through the footing, then get a re-inspection.
- Dec 22, 2025
Foundation Pre-Backfil
ApprovedInspectorScot Jandro
- Dec 22, 2025
CMU Fdn Reinforcement
ApprovedInspectorScot Jandro
- Dec 12, 2025
Footing
ApprovedInspectorScot Jandro
Received picture of scrapped footing
- Dec 10, 2025
Footing
Partial ApprovalInspectorScot Jandro
dewater lower footing, scrape out muck 20x8 w/#4 rebar
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.